PLP-60-48

SPECIFICATION
MODEL PLP-60-12 PLP-60-24 PLP-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP TIME
VOLTAGE RANGE
Note.4
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (max.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
Note.5
SHORT CIRCUIT
OVER VOLTAGE
12V 24V 48V
18 ~ 24V 36 ~ 48V
5A
0 ~ 5A
2.5A
0 ~ 2.5A
1.3A
0 ~ 1.3A
60W 60W 62.4W
4.5Vp-p 4.5Vp-p
1.875 ~ 2.5A
4.8Vp-p
0.975 ~ 1.3A
±10%
±3.0%
±5.0%
500ms / 230VAC 1200ms / 115VAC at full load
47 ~ 63Hz
PF 0.9 at 75 ~ 100% load, 115VAC / 230VAC
84% 88% 89%
15 ~ 18V 28 ~ 35V 57 ~ 63V
0.8A/115VAC 0.4A/230VAC
<0.75mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-30 ~ +70 (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
583.3K hrs min. MIL-HDBK-217F (25 )
101.6*50.8*29.6mm (L*W*H)
0.16Kg; 96pcs/16.4Kg/0.89CUFT
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Built-in active PFC function
Cooling by free air convection
Class 2 power unit
Output current level adjustable
100% full load burn-in test
High reliability
Suitable for built-in applications of LED lighting
2 years warranty
Features :
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to GB17625,GB17743, EN55015, EN61000-3-2 Class C( 75% load); EN61000-3-3 ,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61547, light industry level, criteria A,EAC TP TC 020
3.75 ~ 5A
100 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
Hiccup mode, recovers automatically after fault condition is removed
60W Single Output LED Power Supply
PLP-60 series
File Name:PLP-60-SPEC 2018-01-11
9 ~ 12V
EMC IMMUNITY
EMC EMISSION
GB19510.1,GB19510.14,UL8750, TUV EN61347-1, EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V) approved ; design refer to UL60950-1
,
EAC TP TC 004
COLD START 35A(t =55 s measured at 50% I ) at 230VACwidth peak
μ
CONSTANT CURRENT REGION
Note.5
90 ~ 264VAC 127 ~ 370VDC
MAX.No. of PSUs on 16A
CIRCUIT BREAKER
32units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
TOTAL HARMONIC DISTORTION
THD< 20% when output loading at 115VAC/230VAC input75%
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. lease refer to "DRIVING METHODS OF LED MODULE".
P
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
11. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
( for 48V only) ( except for 48V )
Bauar
Sicherheit
egel gema
t gepruft
od
be
www.
ID 2000000000
tuv.com
wac g
os
S
&
E
Mechanical Specification
Unit:mm
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ( )
LOAD (%)
-30 -25 -5 0 20 40 50 55 60 70
20
40
60
80
100
INPUT VOLTAGE (V) 60Hz
90 100 125 135 145 155 165 175 180 200 230 264
100
90
80
70
60
50
40
LOAD (%)
(HORIZONTAL)
fosc : 90KHz(115VAC)
120KHz(230VAC)
Block Diagram
50
AC Input Connector (CN1) : JST B3P-VH or equivalent
DC Output Connector (CN2) : JST B2P-VH or equivalent
Pin No.
Pin No.1
1
32
2
Assignment
AssignmentAC/L
+V
AC/N -V
No Pin
Mating Housing
Mating Housing
JST VHR
JST VHR
or equivalent
or equivalent
Terminal
Terminal
JST SVH-21T-P1.1
JST SVH-21T-P1.1
or equivalent
or equivalent
12V
Others
: Grounding Required
DETECTION
PWM & PFC
CIRCUIT
O.L.P.
EMI FILTER
RECTIFIERS
POWER
SWITCHING
FILTER
&
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
&
O.C.P.
CN2
CN1
FS1
1
2
1
2
3
3.175
3.175
95.25
101.6
.
.
HS2HS1
SVR1
PLP-60 series
60W Single Output LED Power Supply
29.6
3max.
4- 3.2ψ
44.45
50.8
1.HS1,HS2 cannot be shorted.
2.HS1 must have safety isolation distance
with system case.
3.M1 is safety ground. For better EMC
performance,Please secure an electrical
connection between M1,M2,M3,and chassis
grounding.
M1
M3
M2
File Name:PLP-60-SPEC 2018-01-11
60
62
64
66
68
70
72
74
76
78
80
82
84
86
88
90
92
94
10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
230V
115V
0.78
0.80
0.82
0.84
0.86
0.88
0.90
0.92
0.94
0.96
0.98
1.00
50% 60% 70% 80% 90% 100%
230V
115V
PLP-60 series possess superior working efficiency that up to 89% can be reached in field applications.
EFFICIENCY (%)
LOAD
Power Factor Characteristic
EFFICIENCY vs LOAD (48V Model)
Constant Current Mode
PF
LOAD
DRIVING METHODS OF LED MODULE
(60W)
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
Typical LED power supply I-V curve
Vo(%)
100
75
50 100
(min.)
Io (%)
Constant
Current area
Hiccup
Protection
In the constant current region, the highest voltage at the output of the driver
depends on the configuration of the end systems.
Should there be any compatibility issues, please contact MEAN WELL.
PLP-60 series
60W Single Output LED Power Supply
File Name:PLP-60-SPEC 2018-01-11

PLP-60-48

Mfr. #:
Manufacturer:
Description:
LED Power Supplies 62.5W 48V 1.3A LED Power Supply
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet