EAIRMBA3

DATASHEET
Infrared Receiver Module
EAIRMBA1 & EAIRMBA3
4
Copyright © 2010, Everlight Americas Inc. Release Date : May 21, 2013. Issue No: 1 Rev 1.
www.everlightamericas.com
Test method
The specified electro-optical characteristics are valid under the following conditions.
1. Measurement environment
A place without extreme light reflections.
2. External light
The environment contains an ordinary, white fluorescent lamp without high frequency modulation. The color
temperature is 2856K and the illumination at the IR receiver is less than 10 Lux (Ev10Lux).
3. Standard transmitter
The test transmitter is calibrated by using the circuit shown in figure 2. The radiation intensity of the transmitter is
adjusted until Vo=400mVp-p. Both, the test transmitter and the photo diode, have a peak wavelength of 940nm.
The photo diode for calibration is PD438B (λp=940nm, Vr=5V).
4. The measurement system is shown in Fig.-3
Fig.-1 Transmitter Wave Form D.U.T output Pulse
Fig.-2 standard transmitter calibration
Fig.-2 standard transmitter calibration Fig.-3 Measuring System
DATASHEET
Infrared Receiver Module
EAIRMBA1 & EAIRMBA3
5
Copyright © 2010, Everlight Americas Inc. Release Date : May 21, 2013. Issue No: 1 Rev 1.
www.everlightamericas.com
Typical Electro-Optical Characteristics Curves
DATASHEET
Infrared Receiver Module
EAIRMBA1 & EAIRMBA3
6
Copyright © 2010, Everlight Americas Inc. Release Date : May 21, 2013. Issue No: 1 Rev 1.
www.everlightamericas.com
Package Dimension
(Dimensions in mm)

EAIRMBA3

Mfr. #:
Manufacturer:
Everlight
Description:
Infrared Receivers 38 KHz Thru-Hole
Lifecycle:
New from this manufacturer.