cui.com
date 06/08/2015 │ page 2 of 6CUI Inc │ SERIES: VSK-S10│ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage
85
100
264
370
Vac
Vdc
frequency 47 440 Hz
current
at 110 Vac
at 230 Vac
230
150
mA
mA
inrush current
at 110 Vac
at 230 Vac
10
20
A
A
input fuse recommended external 2 A/250 V, slow-blow type
temperaturecoefcient ±0.02 %/°C
no load power consumption 0.5 W
OUTPUT
parameter conditions/description min typ max units
capcitive load
3.3 Vdc model
5 Vdc model
9 Vdc model
12 Vdc model
15 Vdc model
24 Vdc model
15,000
12,000
6000
2000
1500
500
μF
μF
μF
μF
μF
μF
line regulation full load ±0.5 %
load regulation at 10 ~ 100% ±1 %
voltage set accuracy
3.3 Vdc model
all other models
±3
±2
%
%
hold-up time at 230 Vac 80 ms
switching frequency 65 kHz
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection
3.3, 5 Vdc models
9 Vdc model
12, 15 Vdc models
24 Vdc model
7.5
15
20
30
Vdc
Vdc
Vdc
Vdc
over current protection 110 %
short circuit protection auto recovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output 4,000 Vac
safety approvals UL60950-1
safety class Class II
conducted emissions CISPR11/EN55011,ClassA,CISPR11/EN55011,ClassB(externalcircuitrequired,seegure2)
radiated emissions CISPR11/EN55011,ClassA,CISPR11/EN55011,ClassB(externalcircuitrequired,seegure2)
ESD IEC/EN61000-4-2 Class B, ±6KV/8KV
radiated immunity IEC/EN61000-4-3 Class A, 10V/m
EFT/burst
IEC/EN61000-4-4 Class B, ±2 kV
IEC/EN61000-4-4ClassB,±4kV(externalcircuitrequired,seegure2)
surge
IEC/EN61000-4-5ClassB,±1kV(externalcircuitrequired,seegure1)
IEC/EN61000-4-5ClassB,±2kV/±4kV(externalcircuitrequired,seegure2)
conducted immunity IEC/EN61000-4-6 Class A, 10 Vr.m.s
For more information, please visit the product page.