Parameter Condition Frequency Min. Typ. Max. Unit
Switching characteristics
Rise/fall time
On/off time
10/90% or 90/10% RF
50% V
CTL
to 90/10% RF
20
20
ns
ns
Input power for 1 dB compression V
BIAS
= 1.8 V, V
CTL
= 0 V/1.8 V
V
BIAS
= 1.8 V, V
CTL
= 0 V/1.8 V
V
BIAS
= open circuit, V
CTL
= 0 V/3.3 V
V
BIAS
= open circuit, V
CTL
= 0 V/3.3 V
3.168–4.752 GHz
6.336–7.920 GHz
3.168–4.752 GHz
6.336–7.920 GHz
18
16
26
24
dBm
dBm
dBm
dBm
Intermodulation intercept point (IP3) For two tone input power 5 dBm/tone
1 MHz spacing,
V
BIAS
= 1.8 V, V
CTL
= 0 V/1.8 V
V
BIAS
= O/C, V
CTL
= 0 V/3.3 V
3.168–4.752 GHz
6.336–7.920 GHz
3.168–4.752 GHz
6.336–7.920 GHz
39
34
47
42
dBm
dBm
Control voltages V
CTL LOW
V
CTL HIGH
= V
BIAS
0
1.8
0.2
3.3
V
V
Supply voltage V
BIAS
1.8 3.3 V
Supply currents V
BIAS
= 1.8 to 3.3 V
V
CTL LOW
, V
CTL HIGH
5
5
µA
µA
Operating Characteristics
V
BIAS
= 1.8 V, V
CTL
= 0 V/1.8 V, T = 25 °C, P
INPUT
= 0 dBm, Z
O
= 50 Ω, unless otherwise noted
Truth Table
Characteristic Value
V
BIAS
voltage range 1.8 < V
BIAS
< 5 V
RF input power @ 3 V 27 dBm
Operating temperature -40 °C to +85 °C
Storage temperature -65 °C to +150 °C
Absolute Maximum Ratings
Performance is guaranteed only under the conditions listed in the specifications table and is
not guaranteed under the full range(s) described by the Absolute Maximum specifications.
Exceeding any of the absolute maximum/minimum specifications may result in permanent
damage to the device and will void the warranty.
CAUTION: Although this device is designed to be as robust as
possible, ESD (Electrostatic Discharge) can damage
this device. This device must be protected at all times
from ESD. Static charges may easily produce poten-
tials of several kilovolts on the human body or
equipment, which can discharge without detection.
Industry-standard ESD precautions must be employed
at all times.
V
BIAS
V
CTL1
V
CTL2
RFc-J
1
RFc-J
2
1 1 0 Insertion loss Isolation
1 0 1 Isolation Insertion loss
"1"= 1.8 to 3.3 V.
"0"= 0 V.
For "1" > 3 V, V
BIAS
is not necessary and may be left open ckt.
Any state other than described in the truth table will put the switch in an undefined state.
2
DATA SHEET • SKY13298-360LF
Skyworks Solutions, Inc. • Phone [781] 376-3000 • Fax [781] 376-3100 • sales@skyworksinc.com • www.skyworksinc.com
July 28, 2008 • Skyworks Proprietary Information • Products and Product Information are Subject to Change Without Notice. • 200797 Rev. C