MAX4271/MAX4272/MAX4273
3V to 12V Current-Limiting Hot-Swap Controllers
with Autoretry, DualSpeed/BiLevel Fault Protection
4 _______________________________________________________________________________________
PARAMETER
SYMBOL
CONDITIONS
TYP
MAX
UNITS
Input Voltage Range
Input can be driven to the absolute
maximum limit without false output
inversion
-0.1
13.2
V
Input Bias Current
I
B
,
COMP
0.001
1 μA
ON Pulse Width Low (Note 7)
t
RESTART
To unlatch a fault MAX4271, MAX4273 with
C
TIM
= IN
20 μs
DIGITAL OUTPUTS (STAT, OUTC)
Output Leakage Current V
STAT
13.2, V
OUTC
13.2 1 μA
Output Voltage Low V
OL
I
SINK
= 1mA 0.4 V
RETRY TIMING (MAX4272, MAX4273)
Retry Timeout Period
t
RETRY
100nF capacitor on C
TIM
(Note 5) 0.5 1 2 s
Default Retry
Timeout Period
t
RETRY
(default)
C
TIM
= no connection 176 µs
UNDERVOLTAGE LOCKOUT (UVLO)
Threshold
V
UVLO
Startup is initiated when this threshold is
exceeded at IN
2.25 2.67
V
Hysteresis
V
U V LO
,
H YS T
100 mV
Delay
t
D
,
UVLO
Time the input voltage must exceed
undervoltage lockout before startup is
initiated
100 150 200 ms
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= +2.7V to +13.2V, T
A
= -40°C to +85°C, unless otherwise noted. Typical values are at V
IN
= +5V and T
A
= +25°C.) (Note 3)
Note 3: All devices are 100% tested at T
A
= +25°C. All temperature limits are guaranteed by design.
Note 4: Startup period is the time during which the slow comparator is ignored and the fast comparator regulates the sense current.
It is measured from the time ON is brought high.
Note 5: Inferred from test with C
TON
= 10nF (MAX4273) and C
TIM
= 1nF.
Note 6: The current available at GATE is a function of V
GATE
(see Typical Operating Characteristics).
Note 7: Guaranteed by design.
MAX4271/MAX4272/MAX4273
3V to 12V Current-Limiting Hot-Swap Controllers
with Autoretry, DualSpeed/BiLevel Fault Protection
_______________________________________________________________________________________ 5
Typical Operating Characteristics
(V
IN
= 5V, R
SENSE
= 100mΩ, C
BOARD
= 47µF, T
A
= +25°C, unless otherwise noted.)
0
0.3
0.2
0.1
0.5
0.4
0.9
0.8
0.7
0.6
1.0
02468101214
SUPPLY CURRENT vs. INPUT VOLTAGE
MAX4271/3-01
V
IN
(V)
SUPPLY CURRENT (mA)
ON = V
IN
I
GATE
= 10μA
ON = GND
-40 -15 10 35 60 85
SUPPLY CURRENT vs. TEMPERATURE
MAX4271/3-02
TEMPERATURE (°C)
0
0.3
0.2
0.1
0.5
0.4
0.9
0.8
0.7
0.6
1.0
SUPPLY CURRENT (mA)
ON = V
IN
V
IN
= 12V
V
IN
= 5V
V
IN
= 3V
180
200
190
220
210
230
240
18
20
19
22
21
23
24
0682 4 10 12 14
SLOW COMPARATOR
RESPONSE TIME vs. INPUT VOLTAGE
MAX4271/3-03
V
IN
(V)
t
CSPD
(μs)
t
CSPD
(ms)
CSPD = 110nF
TIME IN ms
CSPD = 0
TIME IN μs
49.0
49.6
49.4
49.2
50.0
49.8
50.8
50.6
50.4
50.2
51.0
02468101214
SLOW COMPARATOR THRESHOLD
vs. INPUT VOLTAGE
MAX4271/3-04
V
IN
(V)
V
SC,TH
(mV)
T
A
= -40°C
T
A
= +25°C
T
A
= +85°C
200
250
350
300
400
450
1 10 100 1000
FAST COMPARATOR RESPONSE TIME
vs. OVERDRIVE VOLTAGE
MAX4271/3-05
OVERDRIVE VOLTAGE (mV)
RESPONSE TIME (ns)
V
IN
= 12V
V
IN
= 5V
V
IN
= 3V
200
300
400
350
450
500
-40 10-15 35 60 85
FAST COMPARATOR RESPONSE TIME
vs. TEMPERATURE
MAX4271/3-06
TEMPERATURE (°C)
RESPONSE TIME (ns)
V
IN
= 12V
V
IN
= 5V
V
IN
= 3V
250
190
196
194
192
200
198
208
206
204
202
210
FAST COMPARATOR THRESHOLD
vs. INPUT VOLTAGE
MAX4271/3-07
V
FC,TH
(mV)
02468101214
V
IN
(V)
T
A
= -40°C
T
A
= +25°C
T
A
= +85°C
0.1
1
1k
100
10
10k
100k
0.01 10.1 10 100 1000
TIME TO FAST DISCHARGE GATE
vs. C
GATE
MAX4271/3-08
C
GATE
(nF)
TIME TO DISCHARGE GATE (μs)
V
IN
= 12V
V
IN
= 5V
V
IN
= 3V
NO EXTERNAL MOSFET
DISCHARGE TO V
GATE
= 0.1V
250
270
310
290
330
350
042 6 8 101214
STARTUP PERIOD
vs. INPUT VOLTAGE
MAX4271/3-09
V
IN
(V)
t
START
(μs)
25
27
31
29
33
35
t
START
(ms)
C
TIM
= 100nF
TIME IN ms
C
TIM
= 1nF
TIME IN μs
MAX4271/MAX4272/MAX4273
3V to 12V Current-Limiting Hot-Swap Controllers
with Autoretry, DualSpeed/BiLevel Fault Protection
6 _______________________________________________________________________________________
Typical Operating Characteristics (continued)
(V
IN
= 5V, R
SENSE
= 100mΩ, C
BOARD
= 47µF, T
A
= +25°C, unless otherwise noted.)
0
0.4
0.2
0.8
0.6
1.0
1.2
1.6
1.4
1.8
02468101214161820
FAST GATE DISCHARGE CURRENT
vs. V
GATE
MAX4271/3-10
V
IN
(V)
FAST GATE DISCHARGE CURRENT (mA)
V
IN
= 12V
V
IN
= 3V
V
IN
= 5V
0
60
40
20
80
100
120
0862 4 10 12 14 16 18 20
GATE CHARGE CURRENT
vs. GATE VOLTAGE
MAX4271/3-11
V
GATE
(V)
I
GATE
(μA)
V
IN
= 12V
V
IN
= 5.0V
V
IN
= 3.0V
0
50
25
100
75
125
150
-40 10 35-15 60 85
GATE CHARGE CURRENT
vs. TEMPERATURE
MAX4271/3-12
TEMPERATURE (°C)
I
GATE
(μA)
V
IN
= 12V
V
GATE
= 0
V
IN
= 5V
V
IN
= 3V
0
5
15
10
20
25
042 6 8 101214
GATE VOLTAGE vs. INPUT VOLTAGE
MAX4271/3-13
V
IN
(V)
V
GATE
(V)
I
GATE
= 10μA
T
A
= +85°C
T
A
= +25°C
T
A
= -40°C
0
100
50
150
300
350
250
200
400
0 468102 1214161820
SLOW GATE DISCHARGE CURRENT
vs. GATE VOLTAGE
MAX4271/3-13a
V
GATE
(V)
I
GATE
(μA)
V
IN
= 12V
V
IN
= 3V
TRIGGERED BY A FAULT
OR BY ON FALLING
V
IN
= 5V
0.01 0.1 1 10 100 1000
TIME TO CHARGE GATE
vs. C
GATE
MAX4271/3-14
C
GATE
(nF)
TIME TO CHARGE GATE (ms)
1000
0.001
0.01
1
0.1
100
10
NO EXTERNAL MOSFET
V
IN
= 12V
TO V
GATE
= 17V
V
IN
= 5V
TO V
GATE
= 10V
V
IN
= 3V
TO V
GATE
= 6V
1.0
2.5
2.0
1.5
3.0
3.5
4.0
3.0 3.83.63.2 3.4 4.0 4.2 4.4 4.6 4.8 5.0
FAST GATE DISCHARGE CURRENT
vs. V
IN
MAX4271/3-15
FAST GATE DISCHARGE CURRENT (mA)
RISING V
IN
FALLING V
IN
V
IN
(V)
0
100
50
200
150
350
300
250
400
-40 10-15 35 60 85
SLOW GATE DISCHARGE CURRENT
vs. TEMPERATURE
MAX4271/3-16
TEMPERATURE (°C)
I
GATE
(μA)
V
IN
= 3V
V
IN
= 5V, 12V
V
GATE
= V
IN
TRIGGERED BY A FAULT
OR BY ON FALLING
0.01 0.1 1 10 100 1000
TIME TO SLOW DISCHARGE GATE
vs. C
GATE
MAX4271/3-17
C
GATE
(nF)
TIME TO DISCHARGE GATE (ms)
1000
0.001
1
0.1
0.01
10
100
V
IN
= 12V
V
IN
= 5V
V
IN
= 3V
DISCHARGE TO V
GATE
= 0.1V
NO EXTERNAL MOSFET

MAX4272ESA+

Mfr. #:
Manufacturer:
Maxim Integrated
Description:
Hot Swap Voltage Controllers 3-12V Current-Limit Hot Swap Controller
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union