2948801

PHOENIX CONTACT Inc., USA Page 1 / 5
http://www.phoenixcon.com Mar 24, 2010
Extract from the online
catalog
EMG 12-OV- 5DC/240AC/1
Order No.: 2948801
The illustration shows version EMG 12-OV, with AC voltage output, max. 1 A
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2948801
Power optocoupler, with light indicator and protection circuits in the
input and output circuits, input: 5 V DC, output: 24-280 V AC/max. 1 A
Commercial data
EAN 4017918083472
Pack 10 pcs.
Customs tariff 85364190
Weight/Piece 0.04998 KG
Catalog page information Page 129 (IF-2009)
Product notes
WEEE/RoHS-compliant since:
04/01/2007
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Input data
Nominal input voltage U
N
5 V DC
Input voltage range in reference to U
N
0.8 ... 1.1
Switching threshold "0" signal in reference to U
N
≤ 0.4
Switching threshold "1" signal in reference to U
N
≥ 0.8
EMG 12-OV- 5DC/240AC/1 Order No.: 2948801
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2948801
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com Mar 24, 2010
Typical input current at U
N
10 mA
Typical response time (max. one half cycle - zero-voltage crossing)
Typical turn-off time (max. one half cycle - zero-current crossing)
Status display Yellow LED
Name of protection Polarity protection
Surge protection
Protective circuit/component Polarity protection diode
Varistor
Transmission frequency 25 Hz
Output data
Output nominal voltage 240 V AC
Output nominal voltage range 24 V AC ... 280 V AC (50 Hz ... 60 Hz)
Limiting continuous current 1 A
Min. load current 50 mA
Leakage current 3.5 mA
Surge current 125 A (t = 10 ms)
Max. load value
78 A
2
s (I
2
x t where t = 10 ms)
Peak offstate voltage 600 V (Periodic peak reverse voltage)
Voltage drop at max. limiting continuous current ≤ 1.5 V
Output circuit 2-conductor floating
Name of protection RC element
Protective circuit/component RC element
Connection data
Type of connection Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 4 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 2.5 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 12
General data
Width 12.5 mm
EMG 12-OV- 5DC/240AC/1 Order No.: 2948801
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=2948801
PHOENIX CONTACT Inc., USA Page 3 / 5
http://www.phoenixcon.com Mar 24, 2010
Height 102 mm
Depth 75 mm
Test voltage input/output 3.5 kV AC
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -20 °C ... 70 °C
Mounting position Any
Assembly instructions Mounted in rows with zero spacing: Horizontal/not in rows: Any
Operating mode 100% operating factor
Degree of protection IP20
Inflammability class in acc. with UL 94 (housing) V0
Standards/regulations DIN VDE 0110
Rated surge voltage / insulation Basic insulation
Certificates / Approvals
Certification GOST
Accessories
Item Designation Description
Marking
2947035 EMG-GKS 12 Equipment marker, width 12 mm
Diagrams/Drawings
Diagram

2948801

Mfr. #:
Manufacturer:
Phoenix Contact
Description:
Solid State Relays - Industrial Mount EMG 12-OV- 5DC 240AC/1
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet