ADuM260N/ADuM261N/ADuM262N/ADuM263N Data Sheet
Rev. 0 | Page 8 of 23
Parameter Symbol Min Typ Max Unit Test Conditions/Comments
Undervoltage Lockout
Positive V
DDx
Threshold V
DDxUV+
1.6 V
Negative V
DDx
Threshold V
DDxUV−
1.5 V
V
DDx
Hysteresis V
DDxUVH
0.1 V
AC SPECIFICATIONS
Output Rise/Fall Time t
R
/t
F
2.5 ns 10% to 90%
Common-Mode Transient Immunity
7
|CM
H
| 75 100 kV/µs
V
Ix
= V
DDx
, V
CM
= 1000 V,
transient magnitude = 800 V
|CM
L
| 75 100 kV/µs
V
Ix
= 0 V, V
CM
= 1000 V,
transient magnitude = 800 V
1
150 Mbps is the highest data rate that can be guaranteed, although higher data rates are possible.
2
I
Ox
is the Channel x output current, where x = A, B, C, D, E, or F.
3
V
IxH
is the input side logic high.
4
V
IxL
is the input side logic low.
5
V
I
is the voltage input.
6
N0 refers to the ADuM260N0/ADuM261N0/ADuM262N0/ADuM263N0 models. N1 refers to the ADuM260N1/ADuM261N1/ADuM262N1/ADuM263N1 models. See the
Ordering Guide section.
7
|CM
H
| is the maximum common-mode voltage slew rate that can be sustained while maintaining the voltage output (V
O
) > 0.8 V
DDx
. |CM
L
| is the maximum common-
mode voltage slew rate that can be sustained while maintaining V
O
> 0.8 V. The common-mode voltage slew rates apply to both rising and falling common-mode
voltage edges.
Table 6. Total Supply Current vs. Data Throughput
1 Mbps 25 Mbps 100 Mbps
Parameter Symbol Min Typ Max Min Typ Max Min Typ Max Unit
SUPPLY CURRENT
ADuM260N
Supply Current Side 1 I
DD1
10.4 15.4 11.2 18.4 16 24 mA
Supply Current Side 2 I
DD2
3.3 5.3 4.8 7.2 9.8 17.9 mA
ADuM261N
Supply Current Side 1 I
DD1
8.9 14.1 10.1 16.3 14.8 23.6 mA
Supply Current Side 2 I
DD2
5.0 8.7 6.5 11.1 11.4 20.1 mA
ADuM262N
Supply Current Side 1 I
DD1
8.1 12.6 9.4 14.4 14.1 23.2 mA
Supply Current Side 2 I
DD2
6.5 10.2 7.8 12.1 12.4 20.1 mA
ADuM263N
Supply Current Side 1 I
DD1
7.1 11.9 8.5 13.9 13.6 21 mA
Supply Current Side 2 I
DD2
8.3 13.4 9.7 15.2 14.8 21.3 mA