AV4 (FU) Miniature Switches
–4–
AECTB16E 201701-T
Angle terminal
• Right angle terminal
• Left angle terminal
Solder terminal with mounting holes
Pin plunger
External dimensions
Pin plunger
Pin
plunger
Right angle terminal
0.5
0.8
1.9
0.8
1.0
3.1
2.4
0.7
0.6
0.5
0.6
0.65 dia.
7.5
5.08
2.54
2.54
4.0
0.3 max.
(
PT
)
0.75 R
1.0
1.2
1.7
0.550.55
0.11
0.8
2.5
4.5
0.4
4.80
±0.15
(
OP
)
5.2 max.
(
FP
)
Note: All other dimensions of hinge lever type and
simulated roller lever type are the same as
those of straight terminal types.
Pretravel PT, Max. 0.3 mm
Movement Differential MD, Max. 0.1 mm
Overtravel OT, Min. 0.1 mm
Operating Position OP 4.8±0.15 mm
Free Position FP, Max. 5.2 mm
CAD Data
External dimensions
Pin plunger
Pin
plunger
Left angle terminal
3.1
2.4
0.7
0.6
0.5
1.7
0.550.55
0.11
0.8
2.5
0.5
0.8
1.9
0.8
1.0
0.6
0.65 dia.
7.5
5.08
2.54
2.54
4.0
0.3 max.
(
PT
)
0.75 R
1.0
1.2
4.5
0.4
4.80
±0.15
(
OP
)
5.2 max.
(
FP
)
Note: All other dimensions of hinge lever type and
simulated roller lever type are the same as
those of straight terminal types.
Pretravel PT, Max. 0.3 mm
Movement Differential MD, Max. 0.1 mm
Overtravel OT, Min. 0.1 mm
Operating Position OP 4.8±0.15 mm
Free Position FP, Max. 5.2 mm
CAD Data
External dimensions
1.0
2.5
0.6
0.3 max.
(PT)
5.4
(OP)
5.8 max.
(FP)
1.9
7.5
1.65 dia.
4.0
0.8
1.2
1.4
1.4
3.1
1.5
5.1
±0.15
2.5
2.54 2.54
Pretravel PT, Max. 0.3 mm
Movement Differential MD, Max. 0.1 mm
Overtravel OT, Min. 0.1 mm
Operating Position OP 5.4±0.15 mm
Free Position FP, Max. 5.8 mm
CAD Data
AV4 (FU) Miniature Switches
–5–
AECTB16E 201701-T
Hinge lever
Simulated roller lever
CAUTIONS FOR USE
External dimensions
1.65 dia.
0.8
2.5
0.11
0.6
1.5
1.4
1.4
3.1
3.0
6.5
0.81.2
4.0
7.5
4.55
5.1
(
FP
)
9.0 max.
(
OP
)
±0.6
6.4
2.4 max.
(
PT
)
Note: All other dimensions are the same as those of
pin plunger type.
Pretravel PT, Max. 2.4 mm
Movement Differential MD, Max. 0.7 mm
Overtravel OT, Min. 0.4 mm
Operating Position OP 6.4±0.6 mm
Free Position FP, Max. 9.0 mm
CAD Data
External dimensions
2.5
0.11
0.8
0.6 R
5.5
3.0
2.2 max.
(
PT
)
1.65 dia.
6.7
±0.5
(
OP
)
9.4 max.
(FP)
0.7
Note: All other dimensions are the same as those of
pin plunger type.
Pretravel PT, Max. 2.2 mm
Movement Differential MD, Max. 0.7 mm
Overtravel OT, Min. 0.3 mm
Operating Position OP 6.7±0.5 mm
Free Position FP, Max. 9.4 mm
CAD Data
Fastening of the switch body
1) In fastening the switch body, use the
M1.4 screw (3 types ... screw head
diameter from 2.4 dia. to 2.6 dia.), with
tightening torque of not more than 0.098
N·m.
2) In setting the movement after
operation, the over-travel should be set
within the range of the minimum OT
value. Please set up so that a operation
object does not apply force to the switch
body.
Environment
Avoid using and storing these switches in
a location where they will be exposed to
corrosive gases, silicon, or high dust
levels, all of which can have an adverse
effect on the contacts.
Soldering
1) Manual soldering should be
accomplished within 5 seconds with max.
320°C iron. Care should be taken not to
apply force to the terminals during
soldering.
2) Terminal portion must not be moved
within 1 minute after soldering. Also no
tensile strength of lead wires should be
applied to the terminals.
3) When using the angle terminal type,
insert an insulation separator between
the switch body and the PC board
(Insulation separator 0.2 to 0.4mm thick)
to prevent the soldering flux from flowing
under the PC board.
Cleaning
As AV4 (FU) switch is not completely
sealed construction, avoid cleaning.
Selection of switch
Please make your selection so that there
will be no problems even if the operating
characteristics vary up to ±20% from the
standard values.
When switching low-level circuits
(max. 100 mA), Au plated contact
types are recommended.
–1–
AECTB36E 201701-T
(Detection Switches)
TECHNICAL TERMINOLOGY
Technical Terminology & Cautions for Use
Detection Switches
A compact switch equipped with an enclosed micro-gap snap-
action contact mechanism that makes a specified motion with a
specified force to open/close a circuit, and an actuator outside
the enclosure (hereinafter referred to as the switch)
Actuator
A part of the switch that transmits the received external force to
an internal spring mechanism to move the movable contact so
that the switch can be opened and closed
Actuator stopper
A part of the switch to limit the actuator movement in the switch
operation direction
Rated values
Values indicating the characteristics and performance guarantee
standards of the snap-action switches. The rated current and
rated voltage, for instance, assume specific conditions (type of
load, current, voltage, frequency, etc.).
Mechanical life
The service life when operated at a preset operating frequency
without passing electricity through the contacts. (The life test is
performed at a switching frequency of 60 times/minute and
operating speed of 100 mm/second at the regular cam.)
Electrical life
The service life when the rated load is connected to the contact
and switching operations are performed. (The life test is
performed at a switching frequency of 20 times/minute and
operating speed of 100 mm/second at the regular cam.)
Contact form
This refers to the
components
determining the type
of application which
make up the electrical
input/output circuits in
the contact.
Insulation resistance
Resistance between non-continuous terminals, each terminal
and other exposed metal parts and between each terminal and
ground.
Dielectric
Threshold limit value that a high voltage can be applied to a
predetermined measuring location for one minute without
causing damage to the insulation.
Contact resistance
This indicates the electrical resistance at the contact part.
Generally, this resistance includes the conductor resistance of
the spring and terminal portions.
Vibration resistance
Malfunction vibration ... Vibration range where a closed contact
does not open for longer than a specified time due to vibrations
during use of the snap-action switches.
Shock resistance
Shock durability ... Shock range where the mechanical shocks
received during snap-action switches transport and installation
do not damage the parts or harm the operating characteristics.
Malfunction shock ... Shock range where a closed contact does
not open for longer than a specified time due to shocks during
use of the snap-action switches.
SPDT
SPST-NC
SPST-NO
Terminal symbols
COM:
NC:
NO:
COM
NC
NC
NO
NO
COM
COM
Common terminal
Normally closed terminal
Normally open terminal

AV444461

Mfr. #:
Manufacturer:
Panasonic Industrial Devices
Description:
Basic / Snap Action Switches SPDT 0.1A, Hinge Simultd. Roller Levr
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union