MER1 Series
1kVDC Isolated 1W Single Output DC/DC Converters
KDC_MER1.B06 Page 4 of 11
www.murata-ps.com/support
APPLICATION NOTES (continued)
Output Ripple Reduction
By using the values of inductance and capacitance stated, the output ripple at the rated load is lowered to 5mV p-p max.
Component selection
Capacitor: It is required that the ESR (Equivalent Series Resistance) should be as low as possible, ceramic types are recommended.
The voltage rating should be at least twice (except for 15V output), the rated output voltage of the DC/DC converter.
Inductor: The rated current of the inductor should not be less than that of the output of the DC/DC converter. At the rated current, the DC resistance of the inductor
should be such that the voltage drop across the inductor is <2% of the rated voltage of the DC/DC converter. The SRF (Self Resonant Frequency) should be
>20MHz.
DC
DC
L
C
Load
Power
Source
Inductor Capacitor
L, µH SMD Through Hole C, µF
MER1S0505SC 10 82103C 11R103C 4.7
MER1S0509SC 22 82223C 11R223C 2.2
MER1S0512SC 47 82473C 11R473C 1
MER1S0515SC 47 82473C 11R473C 1
MER1S1205SC 10 82103C 11R103C 4.7
MER1S1209SC 22 82223C 11R223C 2.2
MER1S1212SC 47 82473C 11R473C 1
MER1S1215SC 47 82473C 11R473C 1
MER1S1505SC 10 82103C 11R103C 4.7
MER1S1509SC 22 82223C 11R223C 2.2
MER1S1512SC 47 82473C 11R473C 1
MER1S1515SC 47 82473C 11R473C 1
MER1S2405SC 10 82103C 11R103C 4.7
MER1S2409SC 22 82223C 11R223C 2.2
MER1S2412SC 47 82473C 11R473C 1
MER1S2415SC 47 82473C 11R473C 1
MER1S4805SC 10 82103C 11R103C 4.7
MER1S4809SC 22 82223C 11R223C 2.2
MER1S4812SC 47 82473C 11R473C 1
MER1S4815SC 47 82473C 11R473C 1
MER1 Series
1kVDC Isolated 1W Single Output DC/DC Converters
KDC_MER1.B06 Page 5 of 11
www.murata-ps.com/support
TECHNICAL NOTES
ISOLATION VOLTAGE
‘Hi Pot Test’, ‘Flash Tested’, ‘Withstand Voltage’, ‘Proof Voltage’, ‘Dielectric Withstand Voltage’ & ‘Isolation Test Voltage’ are all terms that relate to the same thing, a test voltage,
applied for a specified time, across a component designed to provide electrical isolation, to verify the integrity of that isolation.
Murata Power Solutions MER1 series of DC/DC converters are all 100% production tested at their stated isolation voltage. This is 1kVDC for 1 second.
A question commonly asked is, “What is the continuous voltage that can be applied across the part in normal operation?”
The MER1 has been recognized by Underwriters Laboratory for functional insulation, both input and output should normally be maintained within SELV limits i.e. less than 42.4V
peak, or 60VDC. The isolation test voltage represents a measure of immunity to transient voltages and the part should never be used as an element of a safety isolation system.
The part could be expected to function correctly with several hundred volts offset applied continuously across the isolation barrier; but then the circuitry on both sides of the barrier
must be regarded as operating at an unsafe voltage and further isolation/insulation systems must form a barrier between these circuits and any user-accessible circuitry according
to safety standard requirements.
REPEATED HIGH-VOLTAGE ISOLATION TESTING
It is well known that repeated high-voltage isolation testing of a barrier component can actually degrade isolation capability, to a lesser or greater degree depending on materials,
construction and environment. The MER1 series has toroidal isolation transformers, with no additional insulation between primary and secondary windings of enameled wire. While
parts can be expected to withstand several times the stated test voltage, the isolation capability does depend on the wire insulation. Any material, including this enamel (typically
polyurethane) is susceptible to eventual chemical degradation when subject to very high applied voltages thus implying that the number of tests should be strictly limited. We
therefore strongly advise against repeated high voltage isolation testing, but if it is absolutely required, that the voltage be reduced by 20% from specified test voltage.
This consideration equally applies to agency recognized parts rated for better than functional isolation where the wire enamel insulation is always supplemented by a further
insulation system of physical spacing or barriers.
SAFETY APPROVAL
The MER1 series has been recognized by Underwriters Laboratory (UL) to UL 60950 for functional insulation in a maximum ambient temperature of 85°C and/or case temperature
limit of 130°C (case temperature measured on the face opposite the pins). File number E151252 applies.
The MER1 Series of converters are not internally fused so to meet the requirements of UL 60950 an anti-surge input line fuse should always be used with ratings as defined below.
MER1S05xxSC: 1A
MER1S12xxSC: 0.375A
MER1S15xxSC: 0.375A
MER1S24xxSC: 0.2A
MER1S48xxSC: 0.1A
All fuses should be UL approved and rated to at least the maximum allowable DC input voltage.
MER1 Series
1kVDC Isolated 1W Single Output DC/DC Converters
KDC_MER1.B06 Page 6 of 11
www.murata-ps.com/support
EFFICIENCY VS LOAD
MER1S05XXSC MER1S12XXSC
MER1S15XXSC MER1S24XXSC
MER1S48XXSC
0
10
20
30
40
50
60
70
80
90
0 102030405060708090100
Load (%)
Efficiency (%)
15V
12V
9V
5V
0
10
20
30
40
50
60
70
80
90
0 102030405060708090100
Load (%)
Efficiency (%)
15V
9V
5V
12V
0
10
20
30
40
50
60
70
80
90
0 102030405060708090100
Load (%)
Efficiency (%)
5V
9V
12V
15V
0
10
20
30
40
50
60
70
80
90
0 102030405060708090100
Load (%)
Efficiency (%)
5V
9V
12V
15V
15V
0
10
20
30
40
50
60
70
80
90
0 102030405060708090100
Load (%)
Efficiency (%)
5V
9V
12V

MER1S0515SC

Mfr. #:
Manufacturer:
Murata Power Solutions
Description:
Isolated DC/DC Converters 1W 5Vin 15Vout 67mA 1kVDC Isolated SIP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union