PDU3XVSR6G32B

22.1kW 3-Phase Switched PDU, 220/230V (24 C13
& 6 C19), IEC309 32A Red, 380/400V Input, 6ft
Cord, 0U Vertical, TAA
MODEL NUMBER: PDU3XVSR6G32B
Description
Tripp Lite 3 phase Switched PDU / Power Distribution Unit offers advanced network control and
monitoring with the ability to turn on, turn off, recycle or lock-out power to each individual receptacle,
monitor site electrical conditions and remotely monitor output power consumption per-phase or per-
receptacle. PowerAlert interface supports remote control and custom notification of user-specified
conditions via email, secure web, SNMP, Telnet or SSH interface. Individually switched outlets can be
controlled in real-time to remotely reboot unresponsive network hardware, or be custom programmed for
user-defined power-up and power-down sequences to ensure proper startup of interdependent IT systems
and prevent inrush-related overloads as network equipment is first energized. Unused PDU outlets can be
electronically locked off to prevent the connection of unauthorized hardware. PDU output current
consumption in amps per-phase or per-receptacle can be displayed locally via visual meter or remotely via
web/network interface to warn of potential overloads before critical IT mains or branch breakers trip.
Highly accurate current metering offers +/-1% billing-grade current monitoring and recording ability for
each output phase, breakered load bank and individual outlet.
Features
22.1kW Switched 380/400V input 220/230V output PDU with built-in web/network interface
IEC309 32A Red (3P+N+E) 380/400V 3 phase input with 6 ft. / 1.8m line cord
0U, 70 inch / 178cm vertical form factor
30 switched 220/230V outlets (24 C13, 6 C19) in 6 separately breakered 20A single phase load banks
Supports power-on, power-off or reboot of each outlet on a real-time or programmable basis
Enables reboot of locked equipment, custom power-on/power-off sequences, load shedding of optional
loads and disabling unused outlets
Network interface provides PDU control and data regarding input voltage and load levels per-outlet, per-
Highlights
Switched 22.1kW 3-Phase
380/400V input 220/230V output
PDU
Reports voltage & load per-
outlet or per phase via ethernet
interface
1% billing-grade accuracy;
Digital display reports detailed
status information
70in / 1778mm 0U vertical
format; Toolless button-mount
installation
24 C13 & 6 C19 single phase
outlets; Plug-lock cable retention
inserts
IEC309 32A Red (3P+N+E) 3
phase input; 6 ft. / 1.8m line
cord
TAA Compliant
Package Includes
Switched, vertical rackmount
PDU with pre-installed mounting
buttons
24 C13/C14 and 6 C19/C20
Plug-lock cable retention inserts
Spare installation buttons (2
9mm / 4 6mm), Mounting
brackets
Configuration cable
Owner's manual
1 / 4
Specifications
breaker and per-phase
Built-in local digital display and remote web/network interface reports detailed voltage, amperage and
kilowatt output values per outlet, per breaker and per phase with additional reporting options for power
unbalance percentage, IP address and sensor based temperature and humidity data (requires
ENVIROSENSE sensor)
In-rack environmental reporting with optional ENVIROSENSE temperature / humidity sensor and rack
access notification with up to 4 optional SRSWITCH door sensors
Local display supports electronic 180 degree display rotation for overhead or under-floor input cable
orientation
Supports user-specified alarm notification thresholds
DHCP/Manual configuration support
10/100 Mbps auto-sensing
Real-time clock backup maintains the time of day and date even if the PDU is unpowered
Tiered access privileges allow an administrator and a guest to login via web browser
Alert notifications via email or SNMP traps offer immediate event notification
Firmware upgrade ability supports future product enhancements
Supports HTTP, HTTPS, PowerAlert Network Management System, SMTP, SNMPv1, SNMPv2,
SNMPv3, Telnet, SSH, FTPP, DHCP, BootP, NTP protocols
Fully compatible with FREE PowerAlert Network Management System / NMS Software
Included set of Plug-lock inserts keep C14 and C20 power cords solidly connected to PDU outlets
Toolless mounting supported in button-mount compatible racks, plus nut-and-bolt mounting brackets for
other mounting applications (set of 2 9mm buttons pre-installed, 2 9mm and 4 6mm spare buttons
included)
TAA Compliant
OVERVIEW
UPC Code 037332172143
PDU Type Switched
OUTPUT
Output Capacity Details 23kW (415/240V), 22.2kW (400/230V), 21.1kW (380/220V), 20kW (360/200V) total capacity; 32A max per output
phase (L1, L2, L3); 20A max per breakered outlet bank; 16A max per C19 outlet; 10A max per C13 outlet
Frequency Compatibility 50 / 60 Hz
Output Receptacles (24) C13; (6) C19
Output Nominal Voltage 220 (380V input); 230 (400V input)
Overload Protection 6 20A circuit breakers, 1 per outlet bank
2 / 4
INPUT
PDU Input Voltage 380; 400
Recommended Electrical Service 32A 400/230V with IEC309 32A Red (3P+N+E) outlet
Maximum Input Amps 32
PDU Plug Type IEC-309 32A RED (3P+N+E)
Input Cord Length (ft.) 6
Input Cord Length (m) 1.83
Input Phase 3-Phase
USER INTERFACE, ALERTS & CONTROLS
Reported Load Segments Reports input current per phase (L1, L2, L3), plus output current for each output load bank (B1-B6) and individual
output receptacle (1-30); Outlets are color-coded and labeled for phase and load bank identification; L1-N feeds
black outlets (B1, B4); L2-N feeds dark-gray outlets (B2, B5); L3-N feeds light-gray outlets (B3, B6)
Front Panel LCD Display Large digital display reports Amperage, Kilowatts, Voltage, Unbalance percentage, Temperature* and Humidity*
information (*requires ENIVIROSENSE option); Small digital display provides detail on the measurement the large
display is reporting: Input-phase (L#), Load bank (B#), Sensor (S#), Outlet (##), Load unbalance % (UB), Output
power (OP)
Front Panel LEDs Set of 6 LEDs identify the value displayed on the large digital display: Amperage (A), Kilowatts (kW), Voltage (V),
Unbalance percentage (%UB), Temperature (T), Humidity (%RH); One additional LED for each output receptacle
offers power availability information: GREEN (Power ON, load bank capacity <80%), YELLOW (Power ON, load
bank capacity >80%), RED (Power OFF/undervoltage), RED FLASHING (Power OFF/breaker trip)
Switches Set of UP/DOWN arrow buttons scroll through available Input, Bank, Power, Load balance and Sensor options;
Additional MODE button advances the LEDs to view the next measurement
PHYSICAL
Shipping Dimensions (hwd / in.) 75.870 x 9.650 x 6.890
Shipping Dimensions (hwd / cm) 192.71 x 24.51 x 17.50
Shipping Weight (lbs.) 23.1500
Shipping Weight (kg) 10.50
Unit Dimensions (hwd / in.) 70 x 2.17 x 2.52
Unit Dimensions (hwd / cm) 177,8 x 5,51 x 6,4
Unit Weight (lbs.) 16
Unit Weight (kg) 7.26
Material of Construction Metal
Form Factors Supported Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in button-
mount compatible racks
PDU Form Factor Vertical (0U)
ENVIRONMENTAL
Operating Temperature Range 32 to 122F (0C to 50C)
Storage Temperature Range 5 to 140F (-15C to 60C)
3 / 4

PDU3XVSR6G32B

Mfr. #:
Manufacturer:
Tripp Lite
Description:
Power Outlet Strips PDU 3-Phase Switched 220V/230V 22.1kW C13 C19 IEC309 32A Red 0U
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet