DC/DC Converter
ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
without derating
with derating
-40°C to +85°C
-40°C to +100°C
Maximum Case Temperature +105°C
Temperatur Coefficient
Thermal Impedance 20°C/W
Operating Altitude 2000m
Operating Humidity non-condensing 5% to 95% RH
Pollution Degree PD3
MTBF according to MIL-HDBK-217F, G.B.
+25°C
+85°C
2429 x 10
3
h
593 x 10
3
h
Specifications measured at T
a
= 25°C, nominal input voltage, full load, otherwise noted
REC3A
Series
ECO-3
REV.: 1/2017www.recom-power.com
100
80
60
40
20
0
-40 0 604020-20
100
85
12080
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type Report / File Number Standard
Information Technology Equipment, General Requirements for Safety E224736
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1, 2nd Edition, 2014
Audio/Video, information and communication technology equipment E224736
UL62368-1, 2nd Edition, 2014
CSA C22.2 No. 62368-1, 2014
Audio/video, information and communication technology equipment (CB
Scheme)
L0339m35-CB-1-B1
IEC62368, 2nd Edition, 2014
EN62368, 1st Edition, 2014
RoHs 2
RoHS 10/10, 2011/65/EU + AM-2015/863
EMC Compliance Condition Standard / Criterion
Information technology equipment - Radio disturbance characteristics -
Limits and methods of measurement
(5)
with external components EN55022, Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Air ±8kV and Contact ±4kV
3 V/m
±0.5kV
±0.5kV
3 Vr.m.s
50Hz, 1A/m
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
continued on next page
Notes:
Note5: Meets Class A without external components. For Class B, please see filter suggestion below.
Derating Graph
(@ Chamber and natural convection 0.1m/s)