Micrel, Inc. MIC5206
May 2006
5
M9999-051506
(408) 955-1690
Symbol Parameter Condition Min Typ Max Units
Error Flag Output
V
ERR
Flag Threshold
Undervoltage condition (below nominal)
Note 9
–2 –6 –10 %
V
OL
Output Logic-Low Voltage I
L
= 1mA, undervoltage condition 0.2
0.4
V
I
FL
Flag Leakage Current Flag off, V
FLAG
= 0V to 16V –1 0.1 +1 µA
Notes:
1. Exceeding the absolute maximum rating may damage the device.
2. The device is not guaranteed to function outside its operating rating.
3. The maximum allowable power dissipation at any T
A
(ambient temperature) is P
D(max)
= (T
J(max)
–T
A
) / θ
JA
. Exceeding the maximum allowable power
dissipation will result in excessive die temperature, and the regulator will go into thermal shutdown. The θ
JA
of theMIC5205-x.xBM5 (all versions) is
220°C/W, and the MIC5206-x.xBMM (all versions) is 200°C/W, mounted on a PC board (see “Thermal Considerations” for further details).
4. Output voltage temperature coefficient is defined as the worst case voltage change divided by the total temperature range.
5. Regulation is measured at constant junction temperature using low duty cycle pulse testing. Parts are tested for load regulation in the load range
from 0.1mA to 150mA. Changes in output voltage due to heating effects are covered by the thermal regulation specification.
6. Dropout Voltage is defined as the input to output differential at which the output voltage drops 2% below its nominal value measured at 1Vdifferential.
7. Ground pin current is the regulator quiescent current plus pass transistor base current. The total current drawn from the supply is the sum of the load
current plus the ground pin current.
8. Thermal regulation is defined as the change in output voltage at a time “t” after a change in power dissipation is applied, excluding load or line
regulation effects. Specifications are for a 150mA load pulse at V
IN
= 16V for t = 10ms.
9. The error flag comparator includes 3% hysteresis.