BARO-DO-MIL

Barometer Digital Output Pressure Sensors
16-Mar-03
Asynchronous Command Summary
(1,2)
Command
RD
RM
RO
RP
RR
RS
WD<Mode>
WO<Offset>
U<S/N><Cmd>
Description
Read Mode Setting
Read Model Information
Read User Offset Setting
Read Pressure
Read Device Pressure Range
Read Serial Number
Write Mode Setting (“S” = Standard, “H” = High Resolution)
Write User Offset Setting
Select Unique Part for following command (for multidrop
configurations).
Response
RD=<Mode>
RM=<Model String>
RO=<hhhh>
RP=<hhhh>
RR=<Range String>
RS=<Serial Number String>
WD=<Mode>
WO=<hhhh>
U<S/N><Cmd>
All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
® MICROWIRE/PLUS IS A REGISTERED TRADEMARK OF NATIONAL SEMICONDUCTOR.
Asynchronous Command Notes
NOTE 1: ALL COMMANDS AND RESPONSES ARE IN ASCII CHARACTER FORMAT AND ARE TERMINATED BY A CARRIAGE RETURN (CARRIAGE RETURNS ARE NOT SHOWN IN
COMMAND
AND RESPONSE TABLE). EXAMPLE: THE READ HIGH RESOLUTION PRESSURE COMMAND (REPRESENTED BY: RH<CR>) IS GIVEN BY THE FOLLOWING
THREE
BYTE SEQUENCE: 0X52 0X48 0X0D
NOTE 2: <hhhh> IS A FOUR BYTE ASCII STRING REPRESENTING A 16-BIT SIGNED VALUE. EXAMPLE: RH=2B7D REPRESENTS THE RESPONSE OF AN RH COMMAND WITH
THE
PRESSURE OUTPUT OF 0X2B7D (11,133 DECIMAL) VALUE.
NOTE 3: <LLLL> IS A FOUR BYTE ASCII STRING REPRESENTING THE LOW RESOLUTION OUTPUT (SIMILAR TO THE HIGH RESOLUTION RESPONSE OF NOTE 2)
NOTE 4: <eeee> IS A 16-BIT ERROR CODE. THE REPRESENTATION IS FOUR BYTE ASCII STRING (EXPRESSING A DOUBLE-BYTE OR 16-BITS). A “NO ERRORCONDITION IS
EXPRESSED
AS “0000’ WHERE AN ERROR IS EXPRESSED BY SETTING AN INDIVIDUAL BIT OF THE ERROR WORD AND PRESENTING IT IN ASCII HEX FORMAT.
NOTE 5: {NULL} IS A NULL RESPONSE (NO RESPONSE). THE INTENT UTILITY OF THE COMMAND IS TO APPLY THIS COMMAND IN A MULTIDROP CONFIGURATION (BUSSED
CONFIGURATION
) AND SIMULANEOUSLY CAPTURE THE PRESSURE OF ALL OF THE DEVICES ON THE BUSS. THE CAPTURED READINGS CAN SUBSEQUENTLY BE READ USING
THE
U COMMAND (SELECT UNIQUE PART) INCONJUNCTION WITH THE RC COMMAND. EXAMPLE: U<S/N>RC<CR>