CONTENTS
1. SAFETY REGULATIONS AND INFORMATION
11. SAFETY REGULATIONS AND INFORMATION
Read these operating instructions carefully before starting work on the
device. Observe the following warnings to prevent malfunctions or
danger to persons.
These operating instructions are to be regarded as part of the device.
The device is only to be sold or passed on together with the operating
instructions.
These operating instructions may be duplicated and distributed to inform
about potential dangers and their prevention.
1.1 Hazard levels for warnings
11.1 Hazard levels for warnings
These operating instructions use the following hazard levels to indicate
potentially hazardous situations and important safety regulations:
DANGER
Indicates an imminently hazardous situation which will result in
death or serious injury if the specified actions are not taken.
Compliance with the instructions is imperative.
WARNING
Indicates a potentially hazardous situation which can result in
death or serious injury if the specified actions are not taken.
Exercise extreme caution while working.
CAUTION
Indicates a potentially hazardous situation which can result in
minor or moderate injury or damage to property if the specified
actions are not taken.
NOTE
A potentially harmful situation can occur and, if not avoided, can
lead to property damage.
1.2 Staff qualifications
11.2 Staff qualifications
The device may only be transported, unpacked, installed, operated,
maintained and otherwise used by suitably qualified, trained and
authorized technical staff.
Only authorized specialists are permitted to install the device, to carry
out a test run and to perform work on the electrical installation.
1.3 Basic safety rules
11.3 Basic safety rules
The safety hazards associated with the device must be assessed again
following installation in the final product.
The locally applicable industrial safety regulations are always to be
observed when working on the device.
Keep the workplace clean and tidy. Untidiness in the work area
increases the risk of accidents.
Note the following when working on the device:
; Do not perform any modifications, additions or conversions on the
device without the approval of ebm-papst.
1.4 Voltage
11.4 Voltage
; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
When working on an electrically charged device, stand on a
rubber mat.
21.5 Safety and protective features
21.6 Mechanical movement
21.7 Emissions
21.8 Hot surface
21.9 Transport
21.10 Storage
32. INTENDED USE
43. TECHNICAL DATA
43.1 Product drawing
53.2 Nominal data
53.3 Technical description
53.4 Mounting data
53.5 Transport and storage conditions
64. CONNECTION AND STARTUP
64.1 Mechanical connection
64.2 Electrical connection
64.3 Connecting the cables
74.4 Connection diagram
84.5 Checking connections
84.6 Switching on the device
84.7 Switching off the device
85. MAINTENANCE, MALFUNCTIONS, POSSIBLE
CAUSES AND REMEDIES
95.1 Cleaning
95.2 Safety inspection
95.3 Disposal
Item no. 14915-5-9970 · ENU · Change 99022 · Approved 2018-04-27 · Page 1 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
W2S130-AA25-72
Translation of the original operating instructions
WARNING
Live terminals and connections even with device
switched off
Electric shock
Wait five minutes after disconnecting the voltage at all poles
before opening the device.
CAUTION
In the event of a fault, the rotor and the impeller will be
energized
The rotor and the impeller have basic insulation.
Do not touch the rotor and impeller once installed.
CAUTION
The motor restarts automatically when operating voltage
is applied, e.g. after a power failure.
Risk of injury
Keep out of the device's danger zone.
When working on the device, switch off the line voltage
and ensure that it cannot be switched back on.
Wait until the device comes to a stop.
1.5 Safety and protective features
DANGER
Protective device missing and protective device not
functioning
Without a protective device there is a risk of serious injury, for
instance when reaching into the device during operation.
Operate the device only with a fixed protective device and
guard grille.
The fixed protective device must be able to withstand the
kinetic energy of a fan blade that becomes detached at
maximum speed. There must not be any gaps which it is
possible to reach into with the fingers, for example.
The device is a built-in component. As the operator, you
are responsible for ensuring that the device is secured
adequately.
Stop the device immediately if you notice a missing or
ineffective protective device.
1.6 Mechanical movement
DANGER
Rotating device
Risk of injury to body parts coming into contact with the rotor or
the impeller.
Secure the device against accidental contact.
Before working on the system/machine, wait until all
parts have come to a standstill.
WARNING
Rotating device
Long hair and dangling items of clothing, jewelry and the like
can become entangled and be pulled into the device. Injuries
can result.
Do not wear any loose-fitting or dangling clothing or jewelry
while working on rotating parts.
Protect long hair with a cap.
1.7 Emissions
WARNING
Depending on the installation and operating conditions,
the sound pressure level may exceed 70 dB(A).
Risk of noise-induced hearing loss
Take appropriate technical safety measures.
Protect operating personnel with appropriate safety
equipment such as hearing protection.
Also observe the requirements of local agencies.
1.8 Hot surface
CAUTION
High temperature on motor housing
Risk of burns
Ensure sufficient protection against accidental contact.
1.9 Transport
NOTE
Transporting the device
Transport the device in its original packaging only.
Secure the device so it cannot slip, e.g. by using a
lashing strip.
1.10 Storage
; Store the device, partially or fully assembled, in a dry place,
protected against the weather and free from vibration, in the original
packaging in a clean environment.
; Protect the device against environmental effects and dirt until final
installation.
; We recommend storing the device for no longer than one year in
order to guarantee trouble-free operation and the longest possible
service life.
; Even devices explicitly intended for outdoor use are to be stored as
described prior to commissioning.
; Maintain the storage temperature, see
Chapter 3.5 Transport and storage conditions.
Item no. 14915-5-9970 · ENU · Change 99022 · Approved 2018-04-27 · Page 2 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
Operating instructions
W2S130-AA25-72
Translation of the original operating instructions
2. INTENDED USE
The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.
Intended use also includes
Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.
Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.
Operating the device with all protective devices.
Following the operating instructions.
Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.
Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.
Conveying air that contains abrasive particles.
Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.
Conveying air with high dust content, e.g. suctioning off sawdust.
Operating the device close to flammable materials or components.
Operating the device in an explosive atmosphere.
Using the device as a safety component or to perform safety-related
functions.
Operation with completely or partially disassembled or manipulated
protective devices.
In addition, all applications not listed among the intended uses.
Item no. 14915-5-9970 · ENU · Change 99022 · Approved 2018-04-27 · Page 3 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com

W2S130-AA25-72

Mfr. #:
Manufacturer:
ebm-papst
Description:
AC Fans AC Axial Fan
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet