MYLPW3R34EAFN Specification
7
9.2.4. Remote On/Off Control
Start and halt is possible with a control signal.
While the control signal stops output from DC-DC converter, alarm output does not send any signal.
Start : RC is open or connected to-Vin.
Halt : RC is connected to +Vin.
9.2.5. Alarm Output
ALM pin is down to the same voltage level of-Vin pin and sends an alarm signal. (open-drain output)
Sink current in ALM pin is Max.10mA.
It is possible to halt all of the connected DC-DC converters when any one is halted with over voltage
protection or low voltage protection, with connecting all ALM pins for the application of
parallel/multiple operation with plural DC-DC converters.
The maximum number connecting DC-DC converters is 10pcs for the purpose of halting all DC-DC
converters connected with ALM pin each other.
Please contact us when more than 10pcs.
9.2.6. Synchronous Turn-on/off
It is possible to avoid the unevenness of turn-on timing with unifying the various Turn-on input
voltage to a certain voltage which one DC-DC converter has, and with connecting PO pins each
other for the application of parallel/multiple operation of plural DC-DC converters.
It is necessary to connect PO pins for parallel operation.
The maximum number connecting DC-DC converters is 10pcs for the purpose of synchronous
turn-on/off with connecting PO pins.
Please contact us when more than 10pcs.
9.3. Reliability
9.3.1. Reliability Test Items.
Item Test Condition Criteria
Humidity
According to JIS-C-0022
+40±2℃, 90 to 95%RH, 100 hours.
Leave 4 hours at room temperature.
Temperature
Cycles
Repeat cycle 5 times. Leave 2 hours at room
temperature.
1. –40±3℃/30minutes
2. Room Temp./5-10minutes
3. 85±2℃/30minutes
4. Room Temp./5-10minutes
Mechanical
Vibration
10 to 55Hz, max. 1.5mm amplitude, 1 hour
for each of X, Y, Z directions.
Mechanical
Shock
20G, 1 time for each of X, Y, Z directions.
No damage in appearance and no
deviation of electrical characteristics
before and after the test.
9.3.2. Reliability Prediction (For reference only)
MTBF is 2.81 million hours = 321 years
at 50% nominal output current and Ta=40℃,
calculated by Telcordia SR-332.