PS (ADP4)/PF (ADP1)
ASCTB86E 201407-T1
2. Pressure cycle range (0 to rated pressure)
Tested sample: ADP1131, temperature: 25°C 77°F
Evaluation test
Note: For details other than listed above, please consult us.
Classification Tested item Tested condition Result
Environmental
characteristics
Storage at high temperature
Temperature: Left in a 120°C 248°F constant temperature bath
Time: 1,000 hrs.
Passed
Storage at low temperature
Temperature: Left in a –40°C –40°F constant temperature bath
Time: 1,000 hrs.
Passed
Humidity
Temperature/humidity: Left at 40°C 104°F, 90% RH
Time: 1,000 hrs.
Passed
Temperature cycle
Temperature: –40°C to 120°C –40°F to 248°F
1 cycle: 30 Min.
Times of cycle: 100
Passed
Endurance
characteristics
High temperature/high humidity
operation
Temperature/humidity: 40°C 104°F, 90% RH
Operation times: 10
6
, rated voltage applied
Passed
Mechanical
characteristics
Vibration resistance
Double amplitude: 1.5 mm .059 inch
Vibration: 10 to 55 Hz
Applied vibration direction: X, Y, Z 3 directions
Times: 2 hrs each
Passed
Dropping resistance
Dropping height: 75 cm 29.528 inch
Times: 2 times
Passed
Terminal strength
Pulling strength: 9.8 N {1 kgf}, 10 sec.
Bending strength: 4.9 N {0.5 kgf}, left and right 90° 1 time
Passed
Soldering
resistance
Soldered in DIP soldering bath
Temperature: 230°C 446°F
Time: 5 sec.
Passed
Temperature
Temperature: 260°C 500°F
Time: 10 sec.
Passed
Offset voltage range Output span voltage range
Even after testing for 1 million times,
the variations in the offset voltage and
output span voltage are minimal.
–2
–1
0
0
1
2
1×10
5
5×10
5
1×10
6
Pressure cycle, cycle
Offset voltage range (%FS)
Output span voltage range (%FS)
–2
–1
0
0
1
2
1×10
5
5×10
5
1×10
6
Pressure cycle, cycle