MDD02L-05

2W SIP Package DC-DC Medical Grade Unregulated Converter
Model Encoding
Output voltage ( 55/12/15V ± /± /± /±dc 9 12 15Vdc)
Rated wattage
Input voltage ( 4.5 ~ 5.5V 10.8 ~ 13.2V 21.6 ~ 26.4VL: dc M: dc N: dc),,
Series name
-
12MD 02SL
SIP7 package with international standard pinout
Operating temperature range -40 ~ +85
Medical safety approved (1xMOPP/2xMOOP) according to
ANSI AAMI ES60601 1/-
Low patient leakage current <2 A
μ
Protection: Short circuit(3 second max.)
6KVDC or 4.2VAC hight I/O isolation (Reinforced isolation)
Low cost
3 years warranty
Features
S:Single output
D:Dual output
{
MDS02 & MDD02 series
File Name:MDS02,MDD02-SPEC 2017-07-14
Applications
Description
MDS02 MDD02 2 unregulated medical grade and series are W isolated and module type DC-DC converter
with SIP package. It features international standard pins, a high efficiency up to 8 %, working 7 5 wide
temperature range -40~+ , KVDC . I/P-O/P isolation voltage, short circuit protection, 85 6 or 4 2KVAC hight
etc. The models account for different input voltage ± and various output voltage, 5V/12V/
5V/12V/24V ,10%
15V single output and ± /± V/±12V/±15V dual outputs, which are suitable for systems, for 5V 9 for medical
ultra low leakage current.
Medical devices
Medical oxygen monitor
T scanningC
edical cartsM
ral care equipmentO
ANSI/AAMI
ES60601-1
MODEL SELECTION TABLE
ORDER NO.
INPUT OUTPUT
INPUT CURRENT
OUTPUT
VOLTAGE
CAPACITOR LOAD
(MAX.)
OUTPUT
CURRENT
NO LOAD FULL LOAD
INPUT VOLTAGE
(RANGE)
MDS02L-05
MDS02M-05
MDS02N-05
MDS02L-12
MDS02M-12
MDS02N-12
MDS02L-15
MDS02M-15
MDS02N-15
MDD02L-05
MDD02M-05
MDD02N-05
MDD02L-12
MDD02L-09
MDD02M-12
MDD02M-09
MDD02N-12
MDD02N-09
MDD02L-15
MDD02M-15
MDD02N-15
Normal 5V
(4.5 ~ 5.5V)
Normal 12V
(10.8 ~ 13.2V)
Normal 24V
(21.6 ~ 26.4V)
5V
5V
5V
12V
12V
12V
15V
15V
15V
5V±
5V±
5V±
12V±
9V±
12V±
9V±
12V±
9V±
15V±
15V±
15V±
510mA
215mA
106mA
510mA
205mA
103mA
100mA
106mA
103mA
103mA
103mA
510mA
200mA
500mA
210mA
510mA
500mA
205mA
205mA
510mA
205mA
35mA
15mA
16mA
17mA
17mA
18mA
21mA
24mA
8mA
47mA
9mA
9mA
11mA
11mA
11mA
12mA
65mA
35mA
60mA
47mA
65mA
40 ~ 400mA
40 ~ 400mA
40 ~ 400mA
17 ~ 167mA
17 ~ 167mA
17 ~ 167mA
13 ~ 133mA
13 ~ 133mA
13 ~ 133mA
20 ~ 200mA±
20 ~ 200mA±
20 ~ 200mA±
9 ~ 83mA±
9 ~ 83mA±
9 ~ 83mA±
12 ~ 111mA±
12 ~ 111mA±
12 ~ 111mA±
7 ~ 67mA±
7 ~ 67mA±
7 ~ 67mA±
77%
75%
80%
80%
83%
83%
85%
77%
82%
83%
82%
79%
84%
78%
78%
78%
81%
83%
83%
79%
82%
1000 Fμ
1000 Fμ
1000 Fμ
470 Fμ
470 Fμ
470 Fμ
470 Fμ
470 Fμ
470 Fμ
*470 Fμ
*470 Fμ
*470 Fμ
*220 Fμ
*220 Fμ
*220 Fμ
*470 Fμ
*470 Fμ
*470 Fμ
*220 Fμ
*220 Fμ
*220 Fμ
File Name:MDS02,MDD02-SPEC 2017-07-14
EFFICIENCY
(TYP.)
* For each output
2W SIP Package DC-DC Medical Grade Unregulated Converter
MDS02 & MDD02 series
SPECIFICATION
SAFETY &
EMC
(6)
Note.
WITHSTAND VOLTAGE
ISOLATION LEVEL
ISOLATION RESISTANCE
Conducted EN55011(CISPR11)
Radiated
ESD EN61000-4-2
3500Khrs MIL-HDBK-217F(25 )
EN55011(CISPR11)
EMC EMISSION
VOLTAGE RANGE
SURGE VOLTAGE (100ms max.)
FILTER
PROTECTION
VOLTAGE ACCURACY
RATED POWER
SHORT CIRCUIT
INPUT
OUTPUT
PROTECTION
ENVIRONMENT
WORKING TEMP.
WORKING HUMIDITY
COOLING
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
SOLDERING TEMPERATURE
5Vin models : 9Vdc
12Vin models : 18Vdc
24Vin models : 30Vdc
L: 4.5 ~ 5.5Vdc
M: 10.8 ~ 13.2Vdc
N: 21.6 ~ 26.4Vdc
Internal capacitor
±5.0%
2W
75mVp-p
1.2% for 1% input variation
-40 ~ + (Refer to "Derating Curve")85
20% ~ 90% RH non-condensing
Free-air convection
-55 ~ +1 , 10 ~ 95%25 RH non-condensing
0.02% / (0 ~ 85 )℃℃
1.5mm from case of 1 ~ 3sec./260 max.
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
I/P-O/P:6KVDC or 4.2KVAC
Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC, 50/60Hz
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
5pF
Fuse recommended. 500mA Slow-Blow Type for all models
100KHz
3 second max.
±10%
Parameter Standard
Parameter Standard
Test Level / Note
Test Level / Note
MTBF
DIMENSION (L*W*H)
EMC IMMUNITY
OTHERS
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
19.5*9.8*12.5mm (0.77*0.386*0.492 inch)
PACKING
4.2g
NOTE
1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 f & 47 f capacitor. μμ
3.Line regulation is measured from low line to high line at rated load.
4.Load regulation is measured from 10% to 100% rated load.
5.Patient leakage current(2 f max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.μ
6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please
refer to EMI testing of component power supplies.(as available on http://www.meanwell.com)
File Name:MDS02,MDD02-SPEC 2017-07-14
RIPPLE & NOISE Note.2
LINE REGULATION Note.3
LOAD REGULATION Note.4
SWITCHING FREQUENCY
(Typ.)
ISOLATION CAPACITANCE
(Typ.)
Class B
Class B
Level 2, 8KV contact±
2W SIP Package DC-DC Medical Grade Unregulated Converter
MDS02 & MDD02 series

MDD02L-05

Mfr. #:
Manufacturer:
MEAN WELL
Description:
Isolated DC/DC Converters 4.5-5.5Vin +/-5Vout +/-20-200mA 2W SIP
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union