B88069X4900C103

Surge arrester
2-electrode arrester
Series/Type: N80-A230X
Ordering code: B88069X4900xxxx
a)
Version/Date: Issue 04 / 2006-01-18
Version: 6
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the
table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer
PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or
footer when copying the content.
Identification/Classification 1:
(header 1 + top left header bar)
Surge arrester
Identification/Classification 2:
(header 2 + bottom left header bar)
2-electrode arrester
Ordering code:
(top right header bar)
B88069X4900xxxx
a)
Series/Type:
(top right header bar)
N80-A230X
Preliminary data (optional):
EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X4900xxxx
a)
2-electrode arrester N80-A230X
KB AB E / KB AB PM Issue 04 / 2006-01-18
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Standard size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
Branch exchange (MDF)
Line protection
Subscriber protection
Electrical specifications
DC spark-over voltage
1) 2)
230
± 20
V
%
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 550
< 500
< 700
< 600
V
V
V
V
Service life
8)
10 o
p
erations 50 Hz
;
1 s
10
A
rms
1 o
p
eration 50 Hz
;
0.18 s
(
9 c
y
cles
)
65
A
rms
1 o
p
eration 10/350
µ
s
2.5 k
10 o
p
erations 8/20
µ
s
10 k
1 o
p
eration 8/20
µ
s
12 k
300 operations 10/1000 µs
100 A
Insulation resistance at 100 V
dc
> 10
G
Ω
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 12
~ 0.5
~ 60
V
A
V
Weight ~ 1.5 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red negative
230 YY O
230 - Nominal voltage
YY - Year of production
O - Non radioactive
a)
xxxx = C103 (container with 1000 pcs.)
= C403 (container with 4000 pcs.)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845
Surge arrester B88069X4900xxxx
a)
2-electrode arrester N80-A230X
KB AB E / KB AB PM Issue 04 / 2006-01-18
Please read Cautions and warnings and Page 3 of 4
Important notes at the end of this document.
Dimensional drawing
Cautions and warnings
Surge arresters must not be operated directly in power supply networks.
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
Damaged surge arresters must not be re-used.
Not to scale
Dimensions in mm
Non controlled document

B88069X4900C103

Mfr. #:
Manufacturer:
EPCOS / TDK
Description:
Gas Discharge Tubes - GDTs / Gas Plasma Arrestors N80-A230X
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet