File Name:LPP-150-SPEC 2018-01-12
150W Single Output with PFC Function
LPP-150 series
Universal AC input / Full range
Built-in active PFC function, PF>0.96
Protections: Short circuit / Overload / Over voltage
Protections:Over temperature(option)
Cooling by free air convection
100% full load burn-in test
Fixed switching frequency at PFC:67KHz PWM:134KHz
3 years warranty
■
Features :
20 ~ 90% RH non-condensing
-10 ~ +60 with cooling FAN (Refer to "Derating Curve")℃
-20 ~ +85 , 10 ~ 95% RH℃
±℃ ℃)0.05%/ (0 ~ 50
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
191.8Khrs min. MIL-HDBK-217F (25 )℃
222*75*41mm (L*W*H)
0.62Kg; 24pcs/16.6Kg/1.39CUFT
UL60950-1, TUV EN60950-1 approved
, EAC TP TC 004
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A, EAC TP TC 020
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY(Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING HUMIDITY
WORKING TEMP.
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
SAFETY STANDARDS
ENVIRONMENT
SAFETY &
EMC
(Note 4)
PROTECTION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives.360 360 For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
5. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
LPP-150-3.3 LPP-150-5 LPP-150-7.5 LPP-150-12 LPP-150-13.5 LPP-150-15 LPP-150-24 LPP-150-27 LPP-150-48
3.3V 5V 7.5V 12V 13.5V 15V 24V 27V 48V
30A 30A 20A 12.5A 11.2A 10A 6.3A
0 ~ 6.3A
151.2W
5.6A 3.2A
0 ~ 30A 0 ~ 30A 0 ~ 20A 0 ~ 12.5A 0 ~ 11.2A 0 ~ 10A 0 ~ 5.6A 0 ~ 3.2A
99W 150W 150W 150W 151.2W 150W 151.2W 153.6W
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 150mVp-p 250mVp-p
3.14 ~ 3.63V 4.75 ~ 5.5V 7.13 ~ 8.25V 11.4 ~ 13.2V 12.8 ~ 14.9V 14.3 ~ 16.5V 22.8 ~ 26.4V 25.7 ~ 29.7V 45.6 ~ 52.8V
±2.0% ±2.0% ±2.0% ±2.0% ±1.0% ±1.0% ±1.0%
±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5% ±0.5%
±2.0% ±2.0%
SPECIFICATION
MODEL
DC VOLTAGE
STORAGE TEMP., HUMIDITY
±1.0%±1.0% ±1.0% ±1.0% ±0.5%±1.0%±1.0% ±0.5% ±0.5%
600ms, 30ms at full load
30ms at full load
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF 0.96/230VAC PF 0.97/115VAC at full load≧≧
70%
2.5A/115VAC 1.2A/230VAC
COLD START 55A/230VAC
<3.5mA / 240VAC
105 ~ 150% rated output power
Protection type : Constant current limiting, recovers automatically after fault condition is removed
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
76% 80% 82% 83% 83% 85% 85% 85%
3.63 ~ 4.45V 5.5 ~ 6.75V 8.25 ~ 10.1V 13.2 ~ 16.2V
14.85 ~ 18.2V
16.5~ 20.25V 26.4 ~ 32.4V 29.7 ~ 36.5V 52.8 ~ 64.8V
Protection type : Shut down o/p voltage, re-power on to recover
EMC IMMUNITY