SPECIFICATION CONTROL DRAWING
Page 2 of 2 D
FLDW+1321
Revision
SCD
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 125°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 2500 volts (rms), 60 Hz, 1 minute
FLAMMABILITY: 30 seconds (maximum); 3 in. (maximum); no aming of facial tissue
INSULATION ELONGATION AND TENSILE STRENGTH: Test per WCD 3106
Primary Insulation,
Elongation, 150% (minimum)
Tensile Strength, 2500 lbf/in² (minimum)
JACKET COLOR: White preferred
JACKET CONCENTRICITY: 70% (minimum)
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 200% (minimum)
Tensile Strength, 4500 lbf/in² (minimum)
JACKET FLAWS:
Spark Test, 1.5 kV (rms)
Impulse Dielectric Test, 6.0 kV (peak)
JACKET WALL THICKNESS: Measure per WCD 3106
Lower Limit: Per Table I
Minimum Average: 0.008 inch
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
SHIELD COVERAGE: 85% (minimum)
VOLTAGE WITHSTAND (Post Environmental): 1000 volts (rms), 60 Hz, 1 minute
PART NUMBER:
The “+” in the part number in the upper right hand corner shall be replaced with a letter designator to
dene conductor stranding (see part numbers in table).
C = 19 Strands D = 37 Strands E = Rope Lay
The “*” in the part numbers on Tables I and II shall be replaced by color code designators with a slash
separating the component wire colors and a dash separating the component wire colors from the jacket color.
1/ Example: AWG 16, 19 strands, black and brown component wires; white jacket: FLDWC1321-16-0/1-9
1/ See footer section on page 1
TABLE II. CABLE PERFORMANCE DETAILS
PART NUMBER
1/
BEND TESTING
MANDREL DIAMETER
(inch) (±3%)
WEIGHT
(lb) (±3%)
ACCELERATED AGING
COLD
BEND
ACCELERATED AGING
COLD
BEND
FLDWC1321-26-* 3.00 3.00 .375 1.50
FLDWC1321-24-* 6.00 6.00 .375 1.50
FLDWC1321-22-* 6.00 6.00 .375 3.00
FLDWC1321-20-* 6.00 6.00 .500 3.00
FLDWC1321-18-* 6.00 6.00 .500 3.00
FLDWC1321-16-* 6.00 6.00 1.00 3.00
FLDWC1321-14-* 6.00 6.00 1.00 9.00
FLDWC1321-12-* 10.0 10.0 1.50 9.00
FLDWD1321-12-* 10.0 10.0 1.50 9.00
FLDWD1321-10-* 10.0 10.0 2.00 9.00
FLDWE1321-8-* 18.0 18.0 2.00 15.0