MAX195
16-Bit, 85ksps ADC with 10µA Shutdown
4 _______________________________________________________________________________________
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
VDDD = VDDA = 5.25V, VSSD = VSSA = -5.25V,
BP/UP/SHDN = 0V
CONDITIONS
mW80Power Dissipation
µA0.1 5I
SSA
VSSA Shutdown Supply Current
µA0.1 5I
DDA
VDDA Shutdown Supply Current
µA1.6 5I
DDD
VDDD Shutdown Supply Current
(Note 5)
µA0.1 5I
SSD
VSSD Shutdown Supply Current
UNITSMIN TYP MAXSYMBOLPARAMETER
ELECTRICAL CHARACTERISTICS (continued)
(VDDD = VDDA = +5V, VSSD = VSSA = -5V, f
CLK
= 1.7MHz, V
REF
= +5V, T
A
= T
MIN
to T
MAX
, unless otherwise noted. Typical
values are at T
A
= +25°C.)
TIMING CHARACTERISTICS
(VDDD = VDDA = +5V, VSSD = VSSA = -5V, unless otherwise noted.)
Note 1: Accuracy and dynamic performance tests performed after calibration.
Note 2: Guaranteed by design, not tested.
Note 3: Tested with 50% duty cycle. Duty cycles from 25% to 75% at 1.7MHz are acceptable.
Note 4: See
External Clock
section.
Note 5: Measured in shutdown mode with CLK and SCLK low.
POWER REQUIREMENTS (cont.)
PARAMETER SYMBOL CONDITIONS
T
A
= +25°C
TYP
T
A
= 0°C to
+70°C
MIN MAX
T
A
= -40°C to
+85°C
MIN MAX
T
A
= -55°C to
+125°C
MIN MAX
UNITS
CONV Pulse Width
t
CW
20 30 35 ns
CONV to CLK Falling
Synchronization (Note 2)
t
CC1
10 10 10 ns
CONV to CLK Rising
Synchronization (Note 2)
t
CC2
40 40 ns
Data Access Time t
DV
C
L
= 50pF 80 80
40
ns
Bus Relinquish Time t
DH
C
L
= 10pF 40 40 40 ns
CLK to EOC High
t
CEH
C
L
= 50pF 300 300 350 ns
CLK to EOC Low
t
CEL
C
L
= 50pF 300 300 350 ns
CLK to DOUT Valid t
CD
C
L
= 50pF 100 350 100 375 100 400 ns
SCLK to DOUT Valid t
SD
C
L
= 50pF 20 140 20 160 20 160 ns
CS to SCLK Setup Time
t
CSS
75 75 75 ns
CS to SCLK Hold Time
t
CSH
-10 -10 -10 ns
Acquisition Time t
AQ
2.4 2.4 2.4 µs
Calibration Time t
CAL
14,000 x t
CLK
8.2 8.2 8.2 ms
RESET to CLK Setup Time
t
RCS
-40 -40 -40 ns
RESET to CLK Hold Time
t
RCH
120 120 120
Start-Up Time (Note 6) t
SU
Exiting
shutdown
50
ns
90
µs
Note 6: Settling time required after deasserting shutdown to achieve less than 0.1LSB additional error.
_______________Detailed Description
The MAX195 uses a successive-approximation register
(SAR) to convert an analog input to a 16-bit digital
code, which outputs as a serial data stream. The data
bits can be read either during the conversion, at the
CLK clock rate, or between conversions asynchronous
with CLK at the SCLK rate (up to 5Mbps).
The MAX195 includes a capacitive digital-to-analog
converter (DAC) that provides an inherent track/hold
input. The interface and control logic are designed for
easy connection to most microprocessors (µPs), limiting
the need for external components. In addition to the
SAR and DAC, the MAX195 includes a serial interface, a
sampling comparator used by the SAR, ten calibration
DACs, and control logic for calibration and conversion.
The DAC consists of an array of 16 capacitors with
binary weighted values plus one “dummy LSB” capaci-
tor (Figure 1). During input acquisition in unipolar
mode, the array’s common terminal is connected to
AGND and all free terminals are connected to the input
signal (AIN). After acquisition, the common terminal is
disconnected from AGND and the free terminals are
disconnected from AIN, trapping a charge proportional
to the input voltage on the capacitor array.
The free terminal of the MSB (largest) capacitor is con-
nected to the reference (REF), which pulls the common
terminal (connected to the comparator) positive.
Simultaneously, the free terminals of all other capaci-
tors in the array are connected to AGND, which drives
the comparator input negative. If the analog input is
near V
REF
, connecting the MSB’s free terminal to REF
only pulls the comparator input slightly positive.
However, connecting the remaining capacitor’s free ter-
minals to ground drives the comparator input well
below ground, so the comparator input is negative, the
comparator output is low, and the MSB is set high. If
the analog input is near ground, the comparator output
is high and the MSB is low.
Following this, the next largest capacitor is disconnect-
ed from AGND and connected to REF, and the com-
parator determines the next bit. This continues until all
bits have been determined. For a bipolar input range,
the MSB capacitor is connected to REF rather than AIN
during input acquisition, which results in an input range
of V
REF
to -V
REF
.
MAX195
16-Bit, 85ksps ADC with 10µA Shutdown
_______________________________________________________________________________________ 5
______________________________________________________________Pin Description
PIN NAME FUNCTION
1
BP/UP/SHDN
Bipolar/Unipolar/Shutdown Input. Three-state input selects bipolar or unipolar input range, or shutdown.
0V = shutdown, +5V = unipolar, floating = bipolar.
2 CLK Conversion Clock Input
3 SCLK Serial Clock Input is used to shift data out between conversions. May be asynchronous to CLK.
4 VDDD +5V Digital Power Supply
5 DOUT Serial Data Output, MSB first
6 DGND Digital Ground
7
EOC
End-of-Conversion/Calibration Output—normally low. Rises one clock cycle after the beginning of conversion
or calibration and falls one clock cycle after the end of either. May be used as an output framing signal.
8
CS
Chip-Select Input—active low. Enables the serial interface and the three-state data output (DOUT).
9
CONV
Convert-Start Input—active low. Conversion begins on the falling edge after CONV goes low if the input
signal has been acquired; otherwise, on the falling clock edge after acquisition.
10
RESET
Reset Input. Pulling RESET low places the ADC in an inactive state. Rising edge resets control logic and
begins calibration.
11 VSSD -5V Digital Power Supply
12 REF Reference Input, 0 to 5V
13 AIN Analog Input, 0 to V
REF
unipolar or ±V
REF
bipolar range
14 AGND Analog Ground
15 VSSA -5V Analog Power Supply
16 VDDA +5V Analog Power Supply
MAX195
Calibration
In an ideal DAC, each of the capacitors associated with
the data bits would be exactly twice the value of the
next smaller capacitor. In practice, this results in a
range of values too wide to be realized in an economi-
cally feasible size. The capacitor array actually consists
of two arrays, which are capacitively coupled to reduce
the LSB array’s effective value. The capacitors in the
MSB array are production trimmed to reduce errors.
Small variations in the LSB capacitors contribute
insignificant errors to the 16-bit result.
Unfortunately, trimming alone does not yield 16-bit per-
formance or compensate for changes in performance
due to changes in temperature, supply voltage, and
other parameters. For this reason, the MAX195 includes
a calibration DAC for each capacitor in the MSB array.
These DACs are capacitively coupled to the main DAC
output and offset the main DAC’s output according to
the value on their digital inputs. During calibration, the
correct digital code to compensate for the error in each
MSB capacitor is determined and stored. Thereafter,
the stored code is input to the appropriate calibration
DAC whenever the corresponding bit in the main DAC
is high, compensating for errors in the associated
capacitor.
The MAX195 calibrates automatically on power-up. To
reduce the effects of noise, each calibration experiment
is performed many times and the results are averaged.
Calibration requires about 14,000 clock cycles, or
8.2ms at the highest clock (CLK) speed (1.7MHz). In
addition to the power-up calibration, bringing RESET
low halts MAX195 operation, and bringing it high again
initiates a calibration (Figure 2).
16-Bit, 85ksps ADC with 10µA Shutdown
6 _______________________________________________________________________________________
MSB
AIN
REF
AGND
DUMMYLSB
32,768C
16,384C 4C 2C C C
EOC
CLK
RESET
CALIBRATION
BEGINS
CALIBRATION
ENDS
MAX195
OPERATION HALTS
t
CAL
t
RCS
t
RCH
Figure 1. Capacitor DAC Functional Diagram
Figure 2. Initiating Calibration