MP5013A – 5 V, 1 A-5 A PROGRAMMABLE CURRENT LIMIT SWITCH
MP5013A Rev. 1.0 www.MonolithicPower.com 4
6/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2012 MPS. All Rights Reserved.
TYPICAL PERFORMANCE CHARACTERISTICS
V
IN
= 5 V, V
EN
= 5 V, R
LIMIT
= 22 Ω, C
OUT
= 10 F, C
DV/DT
= float, T
A
= 25°C, unless otherwise noted.
0
1
2
3
4
5
6
7
10 20 30 40 50 60 70 80 90100
600
650
700
750
800
850
900
950
3 3.5 4 4.5 5 5.5
300
350
400
450
500
550
600
650
3 3.5 4 4.5 5 5.5
30
35
40
45
50
55
3 3.5 4 4.5 5 5.5
0
20
40
60
80
100
120
0 0.5 1 1.5 2
2
2.5
3
3.5
4
3 3.5 4 4.5 5 5.5
0
1
2
3
4
5
6
3 3.5 4 4.5 5 5.5
0
3
6
9
12
15
4 8 12 16 20
MP5013A – 5 V, 1 A-5 A PROGRAMMABLE CURRENT LIMIT SWITCH
MP5013A Rev. 1.0 www.MonolithicPower.com 5
6/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2012 MPS. All Rights Reserved.
TYPICAL PERFORMANCE CHARACTERISTICS
(continued)
V
IN
= 5 V, V
EN
= 5 V, R
LIMIT
= 22 Ω, C
OUT
= 10 F, C
DV/DT
= Float, T
A
= 25°C, unless otherwise noted.
Start-Up through Input Voltage
No Load
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
Start-Up through Enable
No Load
Shutdown through
Input Voltage
No Load
Shutdown through Enable
No Load
MP5013A – 5 V, 1 A-5 A PROGRAMMABLE CURRENT LIMIT SWITCH
MP5013A Rev. 1.0 www.MonolithicPower.com 6
6/18/2015 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited.
© 2012 MPS. All Rights Reserved.
TYPICAL PERFORMANCE CHARACTERISTICS
(continued)
V
IN
= 5 V, V
EN
= 5 V, R
LIMIT
= 22 Ω, C
OUT
= 10 F, C
DV/DT
= float, T
A
= 25°C, unless otherwise noted.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
1A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
V
OUT
2V/div.
V
IN
5V/div.
V
EN
5V/div.
I
OUT
2A/div.
Short Circuit before Input
Voltage Start-Up and Thermal
Shutdown
Short Circuit during normal
Operation and Thermal
Shutdown
Current Limit Start-Up into OVP
V
IN
= 16V
V
OUT
2V/div.
I
OUT
2A/div.

MP5013AGJ-Z

Mfr. #:
Manufacturer:
Monolithic Power Systems (MPS)
Description:
Hot Swap Voltage Controllers 5V 5A Programmable Current Limit Switch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet