Lineage Power 15
Data Sheet
April 2008
36 Vdc to 75 Vdc Inputs; 20 W
LW020 Single-Output-Series Power Modules:
Recommended Hole Pattern
Component-side footprint.
Dimensions are in millimeters and (inches).
8-1198(C).g
Ordering Information
Table 4. Device Codes
Optional features may be ordered using the device code suffixes shown. To order more than one option, list suf-
fixes in numerically descending order. Please contact your
Lineage Power Account Manager or Field Applica-
tion Engineer for pricing and availability.
Table 5. Device Options
Input Voltage Output Voltage Output Power Device Code Comcode
48 V 2.5 V 10 W LW020G 108258195
48 V 3.3 V 13.2 W LW020F 107640807
48 V 5 V 20 W LW020A 107314304
48 V 12 V 20 W LW020B 107681033
48 V 15 V 20 W LW020C 107640799
Option Device Code Suffix
Short pins: 2.79 mm ± 0.25 mm
(0.110 in. ± 0.010 in.)
8
Case ground pin 7
Short pins: 3.68 mm ± 0.25 mm
(0.145 in. ± 0.010 in.)
6
Synchronization 3
Negative remote on/off logic 1
CASE OUTLINE
DRILL HOLE OF APPROX.
2.54 (0.100) DIAMETER
TO RECESS STANDOFFS
IF LOWER HEIGHT IS NEEDED
5.08
(0.200)
12.7
(0.50)
2.54 (0.100)
50.8 (2.00)
10.16
(0.400)
20.32
(0.800)
37.8
(1.49)
3.43
(0.135)
38.86
(1.530)
7.62 (0.300)
12.4
(0.49)
17.78
(0.700)
50.8
(2.00)
45.72 (1.800)
15.24
(0.600)
2.5
(0.10)