1781-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
CN-A24 Series
Features
14.4 - 36VDC Input
IEC 61373 Shock and Vibration
Base-plate Cooled
Full Power at 100°C base plate
Small Size
Quarter Brick Footprint
Wide input range
50 & 100W 14.4 to 36VDC Input DC-DC Converters
Note: See Installation Manual for full details, test methods of parameters and application notes
(1) Compliant to EN50155 & IEC60571
Model
Nominal Output Voltage VDC 5V 12V 24V
Input Voltage Range VDC 14.4 - 36VDC (40V transient for 3 seconds)
Input Current A 2.48 - 4.91A (model dependant)
Output Voltage Adjustment VDC 4.5 - 6 10.8 - 13.2 21.6 - 26.4
Ripple & Noise (max) pk-pk mV 100 150 240
Line Regulation (max) mV 20 48 96
Load Regulation (max) mV 40 96 192
Overcurrent Protection % 105 - 140%
Overvoltage Protection % 125 - 145% (Cycle input or remote on/off to reset)
Remote Sense - Yes
Remote On/Off - Yes; Low = ON, Open = OFF
Operating Temperature °C -40°C to +100°C Baseplate
Storage Temperature °C -40°C to +100°C
Temperature Coeffi cient %/°C 0.02%/°C
Humidity (non condensing) %RH 5 - 95% RH Operating and Non Operating
Cooling - Conduction (See Installation Manual for heatsink selection)
Withstand Voltage VAC Input to Base-plate: 2kVAC; Input to Output 3.0kVAC for I min.; Output to Base-plate: 500VAC for 1 min
Isolation Resistance - >100M at 25C and 70%RH, Output to Base plate 500VDC
Vibration (1) - Non Operating, 10-55Hz (sweep for 1 min.)
Amplitude 0.825mm constant (Max 49 m/s
2
) X,Y,Z 1 hour each
IEC61373 - Category 1, Grade B
Shock (1) - 196.1m/s
2
, IEC61373 - Category 1, Grade B
Safety Agency Certifi cations - UL60950-1, CSA60950-1, EN60950-1
Weight (Typ) g 70g
Size (WxHxD) in(mm) 1.45 x 0.5 x 2.28” (36.8 x 12.7 x 57.9)
Warranty yrs 5 Years
Specifi cations
Key Market Segments & Applications