AL8806EV6
Issue 1 – June 2011
© Diodes Incorporated 2011
www.diodes.com
2 of 8
Quick Start Guide
Suitable Test Equipment
Count Description Manufacturer Part Number
1
Adjustable Power Supply, 12V
2A
Thurlby Thandar CPX400A
2 Digital Multimeter Fluke 179
1 Digital Storage Oscilloscope Tektronix TDS2024B
2
LED, high brightness, “Dragon
Diamond”, series connected on
suitable heat conducting PCB
Osram
Lamp Operation
1. Set the power supply to 12.0V but do not switch on. Set the current limit to 2.0A.
2. Connect up the AL8806EV6 board to the equipment as in Figure 1 below. Set DMM1 and
DMM2 to measure current up to 2A.
Figure 1: Test Schematic using VDC Input
3. Cover the LEDs to avoid dazzling.
4. Switch on the power supply. This should illuminate the LEDs. Note that the input current
(DMM1) is approximately 690mA. The output current (DMM2) is approximately 1.12A. The
input voltage can be varied from approximately 9VDC to 30VDC and the current regulation
observed is typically within ±2%.
CAUTION: The LEDs are very bright. Ensure
they are hidden from direct view, or covered
with a dispersing filter. The lid from an
aerosol can is convenient for this.
Also the LEDs are very hot. Do not touch!!