RP40-2405SGW/N-HC

PD-4
REV.: 2/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP40-GW
Series
continued on next page
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.333 3.366 3.399 3.432 3.465 3.498 3.531 3.564 3.597 3.63 Volts
R
U
= 57.93 26.16 15.58 10.28 7.11 4.99 3.48 2.34 1.46 0.75 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 3.267 3.234 3.201 3.168 3.135 3.102 3.069 3.036 3.003 2.97 Volts
R
D
= 69.47 31.23 18.49 12.12 8.29 5.74 3.92 2.56 1.50 0.65 kOhms
RP40-xx3.3SGW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 5.05 5.01 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 Volts
R
U
= 36.57 16.58 9.92 6.58 4.59 3.25 2.30 1.59 1.03 0.59 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 Volts
R
D
= 45.53 20.61 12.31 8.15 5.66 4.00 2.81 1.92 1.23 0.68 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts
R
U
= 367.91 165.95 98.64 64.98 44.78 31.32 21.70 14.49 8.88 4.39 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 Volts
R
D
= 460.99 207.95 123.60 81.42 56.12 39.25 27.20 18.16 11.13 5.51 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 Volts
R
U
= 404.18 180.59 106.06 68.80 46.44 31.53 20.88 12.90 6.69 1.72 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 Volts
R
D
= 499.82 223.41 131.27 85.20 57.56 39.14 25.97 16.10 8.42 2.282 kOhms
RP40-xx05SGW
RP40-xx12SGW
RP40-xx15SGW
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 24.24 24.48 24.72 24.96 25.20 25.44 25.68 25.92 26.16 26.40 Volts
R
U
= 218.21 98.10 58.07 38.05 26.04 18.03 12.32 8.03 4.69 2.02 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 23.76 23.52 23.28 23.04 22.80 22.56 22.32 22.08 21.84 21.6 Volts
R
D
= 273.44 123.02 72.87 47.80 32.76 22.73 15.57 10.20 6.02 2.67 kOhms
RP40-xx12DGW
Dual Output Voltage Trim Tables
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP40-GW
Series
PD-5
REV.: 2/2016www.recom-power.com
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 30.30 30.60 30.90 31.20 31.50 31.80 32.10 32.40 32.70 33.00 Volts
R
U
= 268.29 120.64 71.43 46.82 32.06 22.21 15.10 9.91 5.81 2.53 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 29.70 29.40 29.10 28.80 28.50 28.20 27.90 27.60 27.30 27.00 Volts
R
D
= 337.71 152.02 90.13 59.18 40.61 28.23 19.39 12.76 7.60 3.47 kOhms
RP40-xx15DGW
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
3.3Vout
5Vout
12Vout
15Vout
3.9VDC
6.2VDC
15VDC
18VDC
Over Temperature Protection (OTP) 110°C typ.
Over Load Protection (OLP) % of Iout rated 150% max.
Isolation Voltage
I/O to O/P
I/O (O/P) to Case
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
Isolation Resistance 500VDC 1GΩ min.
Isolation Capacitance 2500pF max.
Notes:
Note12: This power module is not internally fused. An input line fuse must always be used.
ENVIRONMENTAL
Parameter Condition
Value
Operating Temperature Range
without derating
with derating
-40°C to +57°C
-40°C to +105°C
Maximum Case Temperature +105°C max.
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance
natural convection (20LFM) without Heat-sink
natural convection (20LFM) with Heat-sink
9.2°C/Watt
7.6°C/Watt
Operating Humidity 5% - 95% RH
Thermal Shock MIL-STD-810F
Vibration MIL-STD-810F
MTBF
MIL-HDBK-217F
Bellcore TR-NWT-000332
(13)
6617 x 10
2
hours
1105 x 10
3
hours
continued on next page
PD-6
REV.: 2/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP40-GW
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety) Report / File Number Standard
UL General Safety E196683
UL60950-1 1st. Ed.: 2003
C22.2 No. 60950 1st. Ed.: 2003
EMC Compliance
Condition
Standard / Criterion
EMI Standard
(15)
with external filter EN55022, Class A or B
ESD
Radiated Immunity
Fast Transient
(16)
Surge
(16)
Conducted Immunity
Air ±8kV and Contact ±6kV
10 V/m
±2kV
±1kV
10 Vr.m.s
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria B
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
continued on next page
Notes:
Note15: The standard modules meet EMI Class A or Class B with external components, see filter suggestions below.
Note16: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5.
The filter capacitor Recom suggest: Nippon chemi-con KY series, 220μF/100V
Derating Graph
(14)
Notes:
Note13 BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment).
Note14: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
-40 60
57
80
100
105
12040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
Output Power [%]
-40 60 80
65
100
105
12040
200-20
0
20
40
60
80
100
Ambient Temperature [°C]
RP40-483.3SGW
RP40-483.3SGW with Heat-sink
Input
Input
DC
DC
Fuse
C2C1
+V
IN
+V
OUT
-V
OUT
-V
IN
LOAD
C4
C3
C3
DC
DC
Fuse
C2
C1
+V
IN
+V
OUT
COM
-V
OUT
-V
IN
LOADLOAD
C4
Input
Input
DC
DC
Fuse
C2C1
+V
IN
+V
OUT
-V
OUT
-V
IN
LOAD
C4
C3
C3
DC
DC
Fuse
C2
C1
+V
IN
+V
OUT
COM
-V
OUT
-V
IN
LOADLOAD
C4
EMI Filtering Class A

RP40-2405SGW/N-HC

Mfr. #:
Manufacturer:
RECOM Power
Description:
Isolated DC/DC Converters 40W DC/DC 1.6kV REG 4:1 9-36Vin 5Vout
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union