https://www.phoenixcontact.com/pi/products/2814126
08/20/2018Page3/4
Temperature measuring transducer-MCR-T-UI-E-NC-2814126
Technical data
Switching output
Output description
Can carry a load of 100 mA, switches supply voltage (not protected
against short-circuit); locked in case of order-specific configuration,
otherwise freely programmable through MCR/PI-CONF-WIN
Output voltage range 18 V DC ... 30 V DC (switches supply voltage, not short-circuit resistant)
Continuous load current 100 mA
Power supply
Supply voltage range 18 V DC ... 30 V DC
Max. current consumption ≤ 60 mA
Typical current consumption 40 mA
Connection data
Connection method Pluggable screw connection
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Stripping length 8 mm
Screw thread M3
General
Maximum transmission error ≤ 0.1 % (of maximum range, ±6 mV or ±12 µA at output)
Maximum temperature coefficient ≤ 0.01 %/K
Temperature coefficient, typical 0.005 %/K
Cold point error, max. ≤ 3 K
Typical cold point errors 1.5 K
Test voltage input/output 1 kV (50 Hz, 1 min.)
Test voltage input/power supply 1 kV (50 Hz, 1 min.)
Color green
Housing material Polyamide PA non-reinforced
Mounting position any
Conformance CE-compliant
UL, USA/Canada Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
GL DNVGL
Standards and Regulations
Connection in acc. with standard CUL
Conformance CE-compliant
UL, USA/Canada Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
GL DNVGL
Environmental Product Compliance