Characteristics STTH15R06
2/9 Doc ID 7974 Rev 2
1 Characteristics
To evaluate the maximum conduction losses use the following equation:
P = 1.16 x I
F(AV)
+ 0.043 I
F
2
(RMS)
Table 2. Absolute ratings (limiting values)
Symbol Parameter Value Unit
V
RRM
Repetitive peak reverse voltage 600 V
I
F(RMS)
Forward rms current 30 A
I
F(AV)
Average forward current 15 A
I
FSM
Surge non repetitive forward current T
p
= 10 ms sinusoidal 150 A
T
stg
Storage temperature range -65 to + 175 °C
T
j
Maximum operating junction temperature 175 °C
Table 3. Thermal parameter
Symbol Parameter Maximum Unit
R
th(j-c)
Junction to case
TO-220AC 1.5
°C/W
TO-220FPAC 4.0
Table 4. Static electrical characteristics
Symbol Parameter Test conditions Min. Typ. Max. Unit
I
R
Reverse leakage
current
T
j
= 25 °C
V
R
= 600 V
60
µA
T
j
= 125 °C 70 800
V
F
Forward voltage drop
T
j
= 25 °C
I
F
= 15 A
2.9
V
T
j
= 125 °C 1.4 1.8