1Description
SIL coupling relay
PSR-PC40
© PHOENIX CONTACT
Data sheet
Intended Use
The PSR-PC40 SIL coupling relay can be used for power
adaptation and electrical isolation in high and low-demand
applications up to SIL3 according to IEC61508 as well as
EN61511.
Using this module, circuits are interrupted in a safety-ori-
ented manner.
The safety relay is equipped with two enabling current paths
that drop out without delay corresponding to stop category0
according to EN60204-1.
By filtering the controller test pulses, premature failure of the
safety relays is prevented.
If an error occurs inside the module, the internal device input
impedance is affected. As such with compatible, safe sys-
tems, the test pulses sent from the controller may be dis-
rupted and the error can be reported back to the corre-
sponding digital output without any additional wiring effort.
The module performs a selftest the moment it is switched on
and prevents the enable contacts from being closed in the
event of an error.
Features
–SIL3 coupling relay for safety-related switching off
Can be used in high and low-demand applications
Approved for Class I, Zone 2 applications
Easy proof test:
-Active error acknowledgment via A1
-Self-monitoring, with device-internal locking
-Visually on the device
Integrated DCS test pulse filter
Low inrush current
2 undelayed enabling current paths
1 digital signal output
Option of screw or spring-cage terminal blocks for plug-
in
12.5mm housing width
Controller-specific Termination Carrier available on re-
quest
WARNING: Risk of electric shock
Observe the safety instructions in the corresponding section!
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
This data sheet is valid for all products listed on the following pages.
106256_en_03
2015-07-14
PSR-PC40
106256_en_03 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Safety notes............................................................................................................................. 6
5.1 Installation in the Ex area (class I, zone 2) .................................................................................. 7
5.2 Installation in areas with a danger of dust explosions .................................................................... 7
6 Basic circuit diagram ............................................................................................................... 8
7 Derating................................................................................................................................... 8
7.1 Vertical mounting position...................................................................................................... 8
7.2 Horizontal mounting position .................................................................................................. 8
7.3 Mounting position with module front at the top............................................................................. 9
8 Load curve............................................................................................................................... 9
8.1 Ohmic load ........................................................................................................................ 9
9 Operating and indication elements ........................................................................................ 10
9.1 Connection versions........................................................................................................... 10
9.2 Connection assignment....................................................................................................... 10
10 Mounting and connection ...................................................................................................... 11
11 Startup................................................................................................................................... 11
12 Proof test ............................................................................................................................... 11
13 Calculating the power dissipation .......................................................................................... 12
14 Application examples ............................................................................................................ 13
14.1 Application example 1 - SIL3................................................................................................ 13
14.2 Application example 2 - SIL3................................................................................................ 13
15 Revision history ..................................................................................................................... 14
PSR-PC40
106256_en_03 PHOENIX CONTACT 3
Description Type Order No. Pcs. / Pkt.
Coupling relay for SIL3 high- and low-demand applications, couples digital
output signals to the I/O, 2 enabling current paths, 1 digital signal output,
safe state off applications, test pulse filter, plug-in screw terminal block
PSR-PC40-2NO-1DO-24DC-SC 2700588 1
Coupling relay for SIL3 high- and low-demand applications, couples digital
output signals to the I/O, 2 enabling current paths, 1 digital signal output,
safe state off applications, test pulse filter, plug-in spring-cage terminal
block
PSR-PC40-2NO-1DO-24DC-SP 2700589 1
3Ordering data
4 Technical data
Hardware/firmware version
HW/FW 00/-- (The technical data and safety characteristics are valid as of the specified
HW/FW version.)
Input data
Rated control supply voltage U
S
24 V DC -15 % / +10 %
Rated control supply current I
S
typ. 75 mA
Typical inrush current 400 mA (t<100s at U
s
)
< 10 mA (Y1-Y2)
Current consumption < 5 mA (Y1-Y2)
Power consumption at U
S
typ. 1.8 W
Voltage at input/start and feedback circuit 24 V DC -15 % / +10 % (Y1-Y2)
Filter time max. 2 ms (at A1-A2; test pulse width)
100 ms (at A1-A2; test pulse rate)
Max. permissible overall conductor resistance
(Input and reset circuit at U
S
)
150 (Y1-Y2)
Typical starting time with U
s
< 200 ms (when controlled via A1; automatic start)
Typical release time with U
s
< 35 ms (when controlled via A1)
Recovery time 500 ms
Maximum switching frequency 0.5 Hz
Operating voltage display 1 x yellow LED
Status display 2 x green LEDs
Indication 1 x red LED
Protective circuit Surge protection Suppressor diode
Reverse polarity protection for rated control supply voltage
Output data
Contact type 2 enabling current paths
Contact material AgSnO
2
Minimum switching voltage 20 V AC/DC
Maximum switching voltage 250 V AC/DC
Nominal current 6 A (see to derating)
Limiting continuous current 6 A (N/O contact)
Maximum inrush current 6 A
Inrush current, minimum 3 mA
Sq. Total current 60 A
2
(see to derating)
Switching capacity min. 60 mW
Mechanical service life 10 x 10
6
cycles
Output fuse 6 A gL/gG (N/O contact)
4 A gL/gG (for low-demand applications)

2700589