ENVIRONMENTAL
Parameter Condition
Operating Temperature Range
without derating
with derating
-40°C to +62°C
-40°C o +101°C
Maximum Case Temperature +105°C max.
Temperature Coefficient ±0.02%/°C max.
Thermal Impedance
natural convection (20LFM) without Heat-sink
natural convection (20LFM) with Heat-sink
12°C/Watt
10°C/Watt
Operating Humidity 5% - 95% RH
Thermal Shock MIL-STD-810F
Vibration MIL-STD-810F
MTBF
MIL-HDBK-217F
Bellcore TR-NWT-000332
(8)
1288 x 10
3
hours
3163 x 10
3
hours
continued on next page
PD-4
REV.: 1/2016 www.recom-power.com
DC/DC Converter
Specifications measured at Ta = 25°C, nominal input voltage, full load otherwise noted
RP30-FW
Series
PROTECTIONS
Parameter Condition Value
Short Circuit Protection (SCP) continuous, automatic recovery
Over Voltage Protection (OVP) Zener Diode Clamp
3.3Vout
5Vout
12Vout
15Vout
3.9VDC
6.2VDC
15VDC
18VDC
Over Load Protection (OLP) % of Iout rated 150% typ.
Over Temperature Protection (OTP)
115°C typ.
Isolation Voltage
I/P to O/P
I/P (O/P) to case
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
Isolation Resistance 500VDC
1GΩ min.
Isolation Capacitance
1500pF max.
Notes:
Note7: This power module is not internally fused. An input line fuse must always be used.
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts
R
U
= 367.91 165.95 98.64 64.98 44.78 31.32 21.70 14.49 8.88 4.39 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 Volts
R
D
= 460.99 207.95 123.60 81.42 56.12 39.25 27.20 18.16 11.13 5.51 kOhms
Trim up 1 2 3 4 5 6 7 8 9 10 %
Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 Volts
R
U
= 404.18 180.59 106.06 68.80 46.44 31.53 20.88 12.90 6.69 1.72 kOhms
Trim down 1 2 3 4 5 6 7 8 9 10 %
Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 Volts
R
D
= 499.82 223.41 131.27 85.20 57.56 39.14 25.97 16.10 8.42 2.282 kOhms
RP30-xx12SFW
RP30-xx15SFW