RATING
1. Coil data
Notes: *1. Square, pulse drive
*2. Maximum allowable voltage is the maximum voltage which can satisfy the coil temperature rise value.
2. Specifications
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
3. Expected electrical life
Condition: Resistive, at 20 times/min.
REFERENCE DATA
Rated voltage
Pick-up voltage*
1
(at 20°C 68°F)
Drop-out voltage*
1
(at 20°C 68°F)
Rated operating current
(DC, ±10%, at 20°C 68°F)
Coil resistance
(±10%, at 20°C 68°F)
Rated operating power
Max. allowable voltage
(at 20°C 68°F)
5V DC
75%V or less of
nominal voltage
(Initial)
5%V or more of
nominal voltage
(Initial)
40.0mA 125Ω
200mW
180%V of
rated voltage*
2
6V DC 33.3mA 180Ω
9V DC 22.2mA 405Ω
12V DC 16.7mA 720Ω
18V DC 11.1mA 1,620Ω
24V DC 8.3mA 2,880Ω
Characteristics Item Specifications
Contact data
Arrangement 1 Form A
Contact resistance (initial) Max. 100 mΩ (By voltage drop 6 V DC 1A)
Contact material AgNi type
Contact rating (resistive) 5A 277V AC, 3A 30V DC
Max. switching power (resistive) 1,385VA, 90W
Max. switching voltage 277V AC, 30V DC
Max. switching current 5A (AC), 3A (DC)
Min. switching load (reference value)*
1
100mA 5V DC
Insulation resistance (initial) Min. 1,000MΩ (at 500V DC) Measured portion is the same as the case of dielectric voltage.
Dielectric strength (initial)
Between open contacts 750 Vrms for 1 min. (detection current: 10 mA)
Between contact and coil 4,000 Vrms for 1 min. (detection current: 10 mA)
Surge withstand voltage
(initial)*
2
Between contact and coil 10,000 V
Operate time (initial) Max. 10 ms (at rated voltage, at 20°C 68°F, excluding contact bounce time)
Release time (initial) Max. 10 ms (at rated voltage, at 20°C 68°F, excluding contact bounce time, with diode)
Shock resistance
Functional 300 m/s
2
(half-wave pulse of sine wave: 11 ms; detection time: 10μs)
Destructive 1,000 m/s
2
(half-wave pulse of sine wave: 6 ms)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10μs)
Destructive 10 to 55 Hz at double amplitude of 1.5 mm
Expected life Mechanical Min. 5×10
6
(at 180 times/min.)
Conditions
Conditions for operation, transport and
storage*
3
Ambient temperature: –40 to +85°C –40 to +185°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 4 g .14 oz
Type Switching capacity Number of operations
1 Form A
5A 125V AC Min. 2×10
5
5A 250V AC Min. 10
5
3A 30V DC Min. 10
5
1. Max. switching capacity 2. Life curve 3. Coil temperature rise (Ave.)
Sample: ALDP112, 6 pcs.
Point measured: inside the coil
Contact current: 0 A, 5 A
10 100
10
5
1
0.1
Contact voltage, V
Contact current, A
AC resistive load
6543210
100
10
1
Contact current, A
125V AC resistive load
250V AC resistive load
Life, ×10
4
5A*
0A*
14012010080
50
40
30
20
10
Coil applied voltage, %V
Temperature rise, °C
*at room temperature
85°C 5A