74AHCT04APWJ

Nexperia
74AHCT04A
Hex inverter
74AHCT04A All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 1 — 22 March 2017
4 / 12
9 Static characteristics
Table 6. Static characteristics
Voltages are referenced to GND (ground = 0 V).
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ Max Min Max Min Max
Unit
V
IH
HIGH-level
input voltage
V
CC
= 4.5 V to 5.5 V 2 - - 2 - 2 - V
V
IL
LOW-level
input voltage
V
CC
= 4.5 V to 5.5 V - - 0.8 - 0.8 - 0.8 V
V
I
= V
IH
or V
IL
; V
CC
= 4.5 V
I
O
= -50 μA 4.4 4.5 - 4.4 - 4.4 - V
V
OH
HIGH-level
output
voltage
I
O
= -8 mA 3.94 - - 3.8 - 3.7 - V
V
I
= V
IH
or V
IL
; V
CC
= 4.5 V
I
O
= 50 μA - 0 0.1 - 0.1 - 0.1 V
V
OL
LOW-level
output
voltage
I
O
= 8 mA - - 0.36 - 0.44 - 0.55 V
I
OFF
power-off
leakage
current
V
I
or V
O
= GND to 5.5 V;
V
CC
= 0 V
- - 0.5 - 5 - 5 μA
I
I
input
leakage
current
V
I
= V
CC
or GND;
V
CC
= 0 V to 5.5 V
- - ±0.1 - ±1 - ±1 μA
I
CC
supply
current
V
I
= V
CC
or GND; I
O
= 0 A;
V
CC
= 5.5 V
- - 2 - 20 - 20 μA
ΔI
CC
additional
supply
current
per input pin; V
I
= 3.4 V;
other pins at V
CC
or GND;
I
O
= 0 A; V
CC
= 5.5 V
- - 1.35 - 1.5 - 1.5 mA
10 Dynamic characteristics
Table 7. Dynamic characteristics
GND = 0 V. For test circuit see Figure 6.
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max Min Max
Unit
nA to nY; see Figure 5
[2]
V
CC
= 4.5 V to 5.5 V
C
L
= 15 pF - 3.1 6.7 1 7.5 1 8.5 ns
t
pd
propagation
delay
C
L
= 50 pF - 4.8 7.7 1 8.5 1 10.0 ns
C
I
input
capacitance
V
I
= V
CC
or GND;
V
CC
= 5 V
- 2 6 - 6 - 6 pF
C
O
output
capacitance
V
O
= V
CC
or GND;
V
CC
= 5 V
- 5 - - - - - pF
Nexperia
74AHCT04A
Hex inverter
74AHCT04A All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 1 — 22 March 2017
5 / 12
25 °C -40 °C to +85 °C -40 °C to +125 °CSymbol Parameter Conditions
Min Typ
[1]
Max Min Max Min Max
Unit
C
PD
power
dissipation
capacitance
per buffer; C
L
= 0 pF;
f = 10 MHz;
V
I
= GND to V
CC
[3]
- 9.3 - - - - - pF
[1] Typical values are measured at T
amb
= 25 °C and V
CC
= 5 V.
[2] t
pd
is the same as t
PLH
and t
PHL
.
[3] C
PD
is used to determine the dynamic power dissipation (P
D
in μW).
P
D
= C
PD
× V
CC
2
× f
i
× N + ∑(C
L
× V
CC
2
× f
o
) where:
f
i
= input frequency in MHz;
f
o
= output frequency in MHz;
C
L
= output load capacitance in pF;
V
CC
= supply voltage in V;
N = number of inputs switching;
∑(C
L
× V
CC
2
× f
o
) = sum of outputs.
Table 8. Noise characteristics
GND = 0 V. For test circuit see Figure 6.
T
amb
= 25 °CSymbol Parameter Conditions
Min Typ Max
Unit
V
CC
= 5 V; C
L
= 50 pF
V
OL(p)
LOW-level output voltage (peak) - 0.4 0.8 V
V
OL(v)
LOW-level output voltage (valley) -0.8 -0.2 - V
V
OH(v)
HIGH-level output voltage (valley) - 4.5 - V
V
IH(AC)
AC HIGH-level input voltage 2 - - V
V
IL(AC)
AC LOW-level input voltage - - 0.8 V
Nexperia
74AHCT04A
Hex inverter
74AHCT04A All information provided in this document is subject to legal disclaimers. © Nexperia B.V. 2017. All rights reserved.
Product data sheet Rev. 1 — 22 March 2017
6 / 12
10.1 Waveforms and test circuit
mna344
t
PHL
t
PLH
V
M
V
M
V
M
V
M
nA input
nY output
GND
V
I
V
OH
V
OL
Measurement points are given in Table 9.
V
OL
and V
OH
are typical voltage output levels that occur with the output load.
Figure 5. Propagation delay input (nA) to output (nY)
Table 9. Measurement points
Input Output
V
M
V
M
1.5 V 0.5V
CC

74AHCT04APWJ

Mfr. #:
Manufacturer:
Nexperia
Description:
Inverters Hex inverter
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet