55A4124-24-9/96-9CS2621

Users should evaluate the suitability of this product for their application. Specications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specication, without notication to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
Page 1 of 1
The TE logo, Tyco Electronics and Raychem are trademarks.
Raychem Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2010 Tyco Electronics Corporation. All rights reserved.
SPECIFICATION CONTROL DRAWING
55A4124
TWO CONDUCTOR CABLE, JACKETED, GENERAL PURPOSE, 600 VOLT 11-2-10 B
This specication sheet forms a part of the latest issue of Raychem Specication 55A.
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
COMPONENT WIRES - 55A0114
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
CABLE CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
JACKET THICKNESS
(in.)
OUTSIDE DIAMETER
(in.)
MAXIMUM
WEIGHT
(lbs/1000 ft.)
MINIMUM NOMINAL NOMINAL MAXIMUM
55A4124-30-* 30 .006 .008 .064 .069 2.6
55A4124-28-* 28 .006 .008 .070 .075 3.3
55A4124-26-* 26 .006 .008 .080 .085 4.5
55A4124-24-* 24 .006 .008 .090 .095 5.9
55A4124-22-* 22 .006 .008 .102 .107 8.0
55A4124-20-* 20 .006 .008 .116 .122 11.4
55A4124-18-* 18 .006 .008 .136 .143 16.1
55A4124-16-* 16 .006 .008 .152 .160 20.2
TITLE
Date
Revision
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms) at sea level
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY (Procedure 1): 3 seconds (maximum);
3 in. (maximum); no aming of facial tissue
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
NOTE: Nominal values are for information only.
Nominal values are not requirements.
LIFE CYCLE: 230 ± 3°C for 500 hours
LOW TEMPERATURE-COLD BEND: -65 ± 2°C for 4 hours
PART NUMBER:
The “*” in the part numbers above shall be replaced by color code
designators with a slash separating the component wire colors and a
dash separating the component wire colors from the jacket color.
1/ Example: AWG 20, black and brown component wires;
white jacket: 55A4124-20-0/1-9

55A4124-24-9/96-9CS2621

Mfr. #:
Manufacturer:
Raychem / TE Connectivity
Description:
Multi-Conductor Cables 55A4124249969CS2621 PRICE PER FOOT
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet