2
40TPS.. SAFEIR Series
Bulletin I2107 rev. G 09/03
www.irf.com
I
T(AV)
Max. Average On-state Current 35 A @ T
C
= 79° C, 180° conduction half sine wave
I
T(RMS)
Max. Continuous RMS 55
On-state Current As AC switch
I
TSM
Max. Peak One Cycle Non-Repetitive 500 A 10ms Sine pulse, rated V
RRM
applied Initial
Surge Current 600 10ms Sine pulse, no voltage reapplied T
J
= T
J
max.
I
2
t Max. I
2
t for Fusing 1250 A
2
s 10ms Sine pulse, rated V
RRM
applied
1760 10ms Sine pulse, no voltage reapplied
I
2
√t Max. I
2
√t for Fusing 12500 A
2
√s t = 0.1 to 10ms, no voltage reapplied
V
T(TO)
1
Low Level Value of Threshold 1.02 V T
J
= 125°C
Voltage
V
T(TO)
2
High Level Value of Threshold 1.23
Voltage
r
t1
Low Level Value of On-state 9.74 mΩ
Slope Resistance
r
t2
High Level Value of On-state 7.50
Slope Resistance
V
TM
Max. Peak On-state Voltage 1.85 V @ 110A, T
J
= 25°C
di/dt Max. Rate of Rise of Turned-on Current 100 A/µs T
J
= 25°C
I
H
Max. Holding Current 150 mA
I
L
Max. Latching Current 300
I
RRM
/ Max. Reverse and Direct 0.5 mA T
J
= 25°C
I
DRM
Leakage Current 10 T
J
= 125°C
dv/dt Max. Rate of Rise 40TPS08 500 V/µs T
J
= T
J
max., linear to 80% V
DRM
, R
g
-k = open
of Off-state Voltage 40TPS12 1000
Voltage Ratings
Part Number
V
RRM
/ V
DRM
, max. repetitive V
RSM
, maximum non repetitive I
RRM
/ I
DRM
peak and off-state voltage peak reverse voltage 125°C
VVmA
40TPS08 800 900 10
40TPS12 1200 1300
Absolute Maximum Ratings
Parameters 40TPS.. Units Conditions
V
R
= rated V
RRM
/ V
DRM