EM-DR1-IC-5-TB-28V/V

Tel: 805-968-0782/800-350-2727 | Fax: 805-968-3154/ 800-960-2726 | 7230 Hollister Ave, Goleta, CA
93117-2807| www.beisensors.com
Specification No. 02125-001 Rev 0713
OPTICAL ISOLATOR
ELECTRONIC MODULE
Output Code Format
From Encoder
Dual Channel in quadrature plus index and complements. Data lines are designated A, B, Z, A/, B/, Z/ at the
module
Output Signal Type
From Encoder
Differential line driver (Use Connection Instructions #1)
Single ended line driver (Use Connection Instructions #2)
Single ended open collector with pull-up resistors internal to encoder (Use Connection Instructions #3)
Single ended, open collector (Use Connection Instructions #3)
Output Signal
Voltage Level From
Encoder
5 VDC (TTL, RS422 compatible, line driver)
12-15 VDC
24VDC
Frequency Response
of Optical Isolator
1 MHz, maximum
Power Requirements
For Optical Isolator
5-28 VDC ±5%, 75mA plus load current
Optical Isolator
Output Options
28V/V Line Driver, 100mA source/sink, Vout = Vin
28V/5 Line Driver, 100mA source/sink, Vout = 5V (Derate output current to 50mA with supply voltage > 12VDC)
28V/OC NPN Open Collector, 80mA sink
Protection Level
Supply lines protected against over voltage to 60 volts and reverse voltage
Tristate Outputs
Available as S Special Feature
ELECTRICAL SPECIFICATIONS
MECHANICAL SPECIFICATIONS
Package dimensions are 114.4 mm high by 99 mm wide by 22.5
mm thick. The package mounts to a DIN rail type EN 50 022
(35mm X 7.5mm). A length of DIN rail is supplied with each
module. The module simply snaps directly to the DIN rail and is
ready to use.
22.5 mm
(0.89 inches)
99 mm
POWER:
The optical isolator can accommodate standard operating
voltages from 5 to 28 VDC. It should never be connected
directly to AC power mains. The module draws approximately
75 mA and a green LED indicates the unit is powered. The
optical isolator module does not provide power to the encoder.
Any encoders used in conjunction with this module must be
connected to their own power.
SIGNAL:
Specifying an optical isolator module requires knowledge of
three system parameters: the DC supply voltage available in the
system; the encoder output type (logic levels and driver type);
and the input signal specifications of the receiving electronics.
This is a versatile interface between an incremental
encoder and receiving electronics. It accepts single
ended or differential inputs and provides single ended or
differential outputs in either an open collector or line
driver configuration. It accommodates all standard
operating voltages from 5 to 28 VDC. Up to eight Optical
Isolator Modules can be daisy-chained to provide
multiple, simultaneous outputs to controllers or PLC’s.
This Optical Isolator can help clean up noisy signals by
converting to a different line driver output. It has a 1
MHz throughput capability and can be used wherever a
fast, optically isolated interface is required.
Tel: 805-968-0782/800-350-2727 | Fax: 805-968-3154/ 800-960-2726 | 7230 Hollister Ave, Goleta, CA
93117-2807| www.beisensors.com
Specification No. 02125-001 Rev 0713
Differential Line Driver
Encoder signals from 5 VDC to 24 VDC (must specify the voltage when ordering)
This is the preferred type of encoder output as it has the best noise immunity. Connect each encoder signal to its like optical isolator
input (A to A, A/ to A/, etc).
Single Ended Line Driver
Encoder signal from 5 VDC to 24 VDC (must specify the voltage when ordering)
Connect encoder output A to optical isolator module input channel A, B to B and Z to Z. Connect the A/, B/, and Z/ inputs of the optical
isolator to circuit common of the encoder supply. Single ended operation is limited to shorter cable runs and is more susceptible to noise.
CONNECTION INSTRUCTIONS #1
Z
Z/
No Connection
No Connection
ENCODER
B/
B
A/
A
CONTROLLER
A
A/
B
B/
Z
Z/
Vs, 5V to 28V
0V, Power Common
A
A
A/
A/
B
B
B/
B/
Z
Z
Z/
Z/
+V
0V
A
A/
B
B/
Z/
Z
+V
0V
REG
VS
0V
Optical Isolator
Encoder Differential Line Driver Output
Figure 1
Standard Connection to
Optical Isolator Module
CONNECTION INSTRUCTIONS #2
A
A
A/
B
B
B/
Z
Z
Z/
+V
0V
A
A/
B
B/
Z/
Z
+V
0V
REG
VS
0V
Optical Isolator
Encoder Single Ended Line Driver Output
Figure 2
Connection Diagram
Single Ended Line Driver
Encoder
Supply
Z
No Connection
Connect A/, B/, Z/ to
Encoder Circuit
Common
ENCODER
B
A
CONTROLLER
A
A/
B
B/
Z
Z/
Vs, 5V to 28V
0V, Power Common
No Connection
Tel: 805-968-0782/800-350-2727 | Fax: 805-968-3154/ 800-960-2726 | 7230 Hollister Ave, Goleta, CA
93117-2807| www.beisensors.com
Specification No. 02125-001 Rev 0713
Open Collector with or without Internal Pull-up Resistors
Encoder NPN (sinking) outputs.
Connect encoder output A to optical isolator module input A/, B to B/ and Z to Z/. Connect the A, B, and Z
inputs of the optical isolator to the auxiliary output terminal on the optical isolator module for 5V module and to
higher voltage when specified by module model and part number. This connection results in a logic inversion
within the optical isolator module. To compensate for the logic reversal, swap A for A/, B for B/, and Z for Z/
at the optical isolator outputs.
Example 1: Resolve an electrical conflict between encoder output and receiving electronics
Sometimes system constraints result in an incompatibility between the encoder output and the receiving electronics or the
cabling. A typical symptom of this problem is missed or intermittent counts. As an example, a single-ended TTL receiver
that is more than 20 feet from the encoder may not be able to compensate for the signal attenuation and ringing caused
by the encoder cabling. An optical isolator module installed near the receiver as shown in Figure 4 can receive the signal,
rejecting the cable effects and produce a signal compatible with the input device.
CONNECTION INSTRUCTIONS #3
Z
Encoder Circuit
Common
ENCODER
B
A
CONTROLLER
A/
A
B/
B
Z/
Z
Vs, 5V to 28V
0V, Power Common
+5 Output
A or A/
A
A/
B or B/
B
B/
Z or Z/
Z
Z/
+V
0V
A
A/
B
B/
Z/
Z
+V
0V
REG
VS
0V
Optical Isolator
Encoder Open Collector Output
Figure 3
Connection Diagram
Open Collector to Optical Module
Optical Regulation
Power Supply
AUX
5V
Uses for Optical Isolator Module
Optical
Isolator
Module
TTL
Single-Ended
Receiver
> 20’
< 6
FIGURE 4
LONG CABLE RUN TO SINGLE ENDED INPUT
To 5 AUX for 5V module.
To 12-15 for 24V dependent
on specified module input
voltage.

EM-DR1-IC-5-TB-28V/V

Mfr. #:
Manufacturer:
BEI Sensors
Description:
OPTICAL ISOLATOR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment: