HJ2-L-AC200V-R-6

HJ
–7–
ASCTB6E 201709-T
3. Plug-in type with a test button (2 Form C)
4. Plug-in type with a test button (4 Form C)
SAFETY STANDARDS
* CSA standard: Certified by C-UL
File No. Certification authority: UL/C-UL File No. Certification authority: TÜV
2 Form C E43149* 7A 250V AC, 7A 30V DC R50049126
7A 250V AC (cos
φ
=1.0), 7A 30V DC (0ms)
Test button type:
10A 250V AC (cos
φ
=1.0), 10A 30V DC (0ms)
4 Form C E43149* 5A 250V AC, 5A 30V DC R50049126 5A 250V AC (cos
φ
=1.0), 5A 30V DC (0ms)
External dimensions
4
58
12
14
9
1
13
Max. 28 Max. 21.5
Max. 36
Max. 38
5.8
+0.4
0.2
.228
+.016
.008
0.5
0.5
2.5
12.7
16.8
6.86.4
13.2
1.102 .846
1.417
1.496
.020
.020
.098
.500
.661
.268.252
.520
Schematic (Bottom view)
Standard type
4
8
12
14
1
5
9
13
LED AC type LED DC type
4
8
12
14
1
5
9
13
4
8
12
1
5
9
14(+)(–)13
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
External dimensions
34
5678
1210 11
14
9
1
13
2
Max. 28 Max. 21.5
Max. 36
Max. 38
5.8
+0.4
0.2
.228
+.016
.008
0.5
0.5
2.5
12.7
16.8
6.86.4
13.24.4
1.102 .846
1.417
1.496
.020
.020
.098
.500
.661
.268.252
.520.173
Schematic (Bottom view)
Standard type
4
8
12
1413
9
5
1
10
6
2
11
7
3
LED AC type LED DC type
1234
5678
1211109
13 14
1234
5678
1211109
14(+)(–)13
CAD Data
Dimension:
Less than 1mm .039inch:
Min. 1mm .039inch less than 3mm .118 inch:
Min. 3mm .118 inch:
Tolerance
±0.1 ±.004
±0.2 ±.008
±0.3 ±.012
       
To Be Discontinued
Last time buy: September 30, 2018
HJ
–8–
ASCTB6E 201709-T
NOTES
1. For cautions for use, please read
“General Application Guidelines”.
2. Coil applied voltage
Please refer to “RATING” about coil input
power supply.
3. LED display
Operation is displayed by the light
emitted from the LED. The LED may
remain briefly lit if voltage remains after
the relay opens.
4. Switching lifetime
The switching lifetime is defined under
the standard test condition specified in
the JIS* C 5442 standard (temperature
15 to 35°C 59 to 95°F, humidity 25 to
75%). Check this with the real device as it
is affected by coil driving circuit, load
type, activation frequency, activation
phase,ambient conditions and other
factors.
Also, be especially careful of loads such
as those listed below.
1) When used for AC load-operating and
the operating phase is synchronous.
Rocking and fusing can easily occur due
to contact shifting.
2) High-frequency load-operating
When high-frequency opening and
closing of the relay is performed with a
load that causes arcs at the contacts,
nitrogen and oxygen in the air is fused by
the arc energy and HNO
3 is formed. This
can corrode metal materials.
Three countermeasures for these are
listed here.
(1) Incorporate an arc-extinguishing
circuit.
(2) Lower the operating frequency
(3) Lower the ambient humidity
5. Usage, transport and storage
conditions
1) Temperature, humidity and pressure
during usage, storage and transport
(1) Temperature:
–40 to +70°C –40 to +158°F
(2) Humidity: 5 to 85% RH
(Avoid freezing and condensation.)
The humidity range varies with the
temperature. Use within the range
indicated in the graph below.
Temperature and humidity range for
usage, transport, and storage
(3) Atmospheric pressure: 86 to 106 kPa
2) Condensation
Condensation forms when there is a
sudden change in temperature under
high temperature and high humidity
conditions. Condensation will cause
deterioration of the relay insulation.
3) Freezing
Condensation or other moisture may
freeze on the relay when the
temperatures is lower than 0°C 32°F. This
causes problems such as sticking of
movable parts or operational time lags.
4) Low temperature, low humidity
environments
The plastic becomes brittle if the relay is
exposed to a low temperature, low
humidity environment for long periods of
time.
6. Operation method for test button
1) Push and release 1 gently to confirm
relay switching.
2) To lock to one side turn 90° counter-
clockwise while pushing lock and turn 90°
clockwise to release.
3) Do not use the test button for anything
other than testing, such as when
checking the circuit.
7. Diode characteristics
1) Reverse breakdown voltage: 1,000 V
2) Forward current: 1 A
8. Diode and CR built-in type
Since the diode and CR inside the relay
coil are designed to absorb the counter
emf, the element may be damaged if a
large surge, etc., is applied to the diode
and CR. If there is the possibility of a
large surge voltage from the outside,
please implement measures to absorb it.
9. Please connect DC coil types with
LED and built-in diode correctly by
verifying the coil polarity (“+” and “–
”). Connecting with reverse polarity
will cause the LED not to light and
damage the built-in diode due to its
specification.
Humidity, %R.H.
Tolerance range
85
5
0 70–40
+32 +158–40
(Avoid
condensation
when used at
temperatures
higher than
0°C
(Avoid freezing
when used at
temperatures
lower than
0°C 32°F)
Temperature, °C °F
32°F)
1
Release
Push
For Lock For Release
       
To Be Discontinued
Last time buy: September 30, 2018
       

HJ2-L-AC200V-R-6

Mfr. #:
Manufacturer:
Panasonic
Description:
General Purpose Relays Control panel Relays with CR circuit
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union