ADM4210 Data Sheet
Rev. A | Page 6 of 16
TYPICAL PERFORMANCE CHARACTERISTICS
4.0
0
0
18
SUPPLY VOLTAGE (V)
SUPPLY CURRENT (mA)
2
4
6
8 10 12 14 16
3.5
3.0
2.5
2.0
1.5
1.0
0.5
T
A
= 25°C
05132-032
Figure 5. Supply Current vs. Supply Voltage
1.0
0
–50 150
TEMPERATURE (°C)
SUPPLY CURRENT (mA)
0.8
0.6
0.4
0.2
–25 0 25 50 75 100 125
V
CC
= 15V
V
CC
= 12V
V
CC
= 5V
V
CC
= 3V
0.9
0.7
0.5
0.3
0.1
05132-033
Figure 6. Supply Current vs. Temperature
2.65
2.45
–50 150
TEMPERATURE (°C)
UVLO THRESHOLD (V)
V
CC
= 5V
–25 0 25 50 75 100 125
2.63
2.61
2.59
2.57
2.55
2.53
2.51
2.49
2.47
V
CC
FALLING
V
CC
RISING
05132-046
Figure 7. UVLO Threshold vs. Temperature
25
0
0 18
SUPPLY VOLTAGE (V)
GATE VOLTAGE (V)
2 4
6 8
10
12 14 16
20
15
10
5
05132-013
Figure 8. GATE Voltage vs. Supply Voltage
25
0
–50 150
TEMPERATURE (°C)
GATE VOLTAGE (V)
20
15
10
5
–25 0
25 50 75 100 125
V
CC
= 15V
V
CC
= 12V
V
CC
= 5V
V
CC
= 3V
05132-015
Figure 9. GATE Voltage vs. Temperature
–8
–14
0 18
SUPPLY VOLTAGE (V)
GATE CURRENTA)
–9
–10
–11
–12
–13
2 4 6 8 10 12 14 16
05132-009
Figure 10. GATE Current (up) vs. Supply Voltage
Data Sheet ADM4210
Rev. A | Page 7 of 16
11.0
–13.0
–50
150
TEMPERATURE (°C)
GATE CURRENTA)
–25
0 25
50
75 100 125
V
CC
= 15V
V
CC
= 12V
V
CC
= 5V
V
CC
= 3V
–11.2
11.4
–1
1.6
–11.8
–12.0
–12.2
–12.4
–12.6
–12.8
05132-017
Figure 11. GATE Current (up) vs. Temperature
10
0
0 18
SUPPLY VOLTAGE (V)
DELTA GATE VOLTAGE (V)
2 4 6 8 10 12 14 16
9
8
7
6
5
4
3
2
1
05132-014
Figure 12. Delta GATE Voltage vs. Supply Voltage
10
0
–50 150
TEMPERATURE (°C)
DELTA GATE VOLTAGE (V)
–25 0 25 50 75 100 125
V
CC
= 15V
V
CC
= 12V
V
CC
= 5V
V
CC
= 3V
9
8
7
6
5
4
3
2
1
05132-016
Figure 13. Delta GATE Voltage vs. Temperature
0
–10
0 18
SUPPLY VOLTAGE (V)
I
TIMERUP
(µA)
2 4 6 8 10
12 14
16
T
A
= 25°C
–1
–2
–3
–4
–5
–6
–7
–8
–9
05132-035
Figure 14. I
TIMERUP
(in Initial Cycle) vs. Supply Voltage
0
–10
–50 150
TEMPERATURE (°C)
I
TIMERUP
(µA)
V
CC
= 5V
–1
–2
–3
–4
–5
–6
–7
–8
–9
–25 0 25 50 75 100 125
05132-038
Figure 15. I
TIMERUP
(in Initial Cycle) vs. Temperature
–20
–100
0 18
SUPPLY VOLTAGE (V)
I
TIMERUP
(µA)
2 4 6 8 10 12 14 16
T
A
= 25°C
–30
–40
–50
–60
–70
–80
–90
05132-036
Figure 16. I
TIMERUP
(During Cct Breaker Delay) vs. Supply Voltage
ADM4210 Data Sheet
Rev. A | Page 8 of 16
–20
–100
–50 150
TEMPERATURE (°C)
I
TIMERUP
(µA)
V
CC
= 5V
–25 0 25 50 75 100 125
–30
–40
–50
–60
–70
–80
–90
05132-039
Figure 17. I
TIMERUP
(During Cct Breaker Delay) vs. Temperature
3.0
1.0
0 18
SUPPLY VOLTAGE (V)
I
TIMERDN
(µA)
2 4 6 8 10 12 14 16
T
A
= 25°C
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
05132-034
Figure 18. I
TIMERDN
(in Cool-Off Cycle) vs. Supply Voltage
3.0
1.0
–50 150
TEMPERATURE (°C)
I
TIMERDN
(µA)
V
CC
= 5V
2.8
2.6
2.4
2.2
2.0
1.8
1.6
1.4
1.2
–25 0 25 50 75 100 125
05132-037
Figure 19. I
TIMERDN
(in Cool-Off Cycle) vs. Temperature
1.38
1.22
0 18
SUPPLY VOLTAGE (V)
TIMER HIGH THRESHOLD (V)
2 4 6 8 10 12
14
16
T
A
= 25°C
1.36
1.34
1.32
1.30
1.28
1.26
1.24
05132-042
Figure 20. TIMER High Threshold vs. Supply Voltage
1.38
1.22
–50 150
TEMPERATURE (°C)
TIMER HIGH THRESHOLD (V)
V
CC
= 5V
–25 0 25 50 75 100 125
1.36
1.34
1.32
1.30
1.28
1.26
1.24
05132-044
Figure 21. TIMER High Threshold vs. Temperature
0.24
0.16
0 18
SUPPLY VOLTAGE (V)
TIMER LOW THRESHOLD (V)
2 4 6 8 10 12 14 16
T
A
= 25°C
0.23
0.22
0.21
0.20
0.19
0.18
0.17
05132-043
Figure 22. TIMER Low Threshold vs. Supply Voltage

ADM4210-1AUJZ-RL7

Mfr. #:
Manufacturer:
Analog Devices Inc.
Description:
Hot Swap Voltage Controllers Simple Hotswap Auto Retry IC
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet