ELG-150 series
SPECIFICATION
MODEL
OUTPUT
VOLTAGE RANGE
Note.5
FREQUENCY RANGE
POWER FACTOR
EFFICIENCY
(Typ.)
AC CURRENT
INPUT
INRUSH CURRENT
(Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
OVER TEMPERATURE
OVER VOLTAGE
1600ms, 80ms/115VAC 500ms, 100ms/230VAC
10ms/115VAC, 230VAC
47 ~ 63Hz
<0.75mA / 277VAC
20 ~ 95% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 60 )
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
ENVIRONMENT
PROTECTION
Shut down output voltage, re-power on to recover
Shut down output voltage, re-power on to recover
SHORT CIRCUIT
TOTAL HARMONIC DISTORTION
DC VOLTAGE
RATED CURRENT
RATED
POWER
VOLTAGE ADJ. RANGE
CURRENT ADJ. RANGE
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.6
HOLD UP TIME (Typ.)
RIPPLE & NOISE
(max.) Note.3
VOLTAGE TOLERANCE
Note.4
CONSTANT CURRENT REGION
Note.2
OVER CURRENT
Adjustable for A/AB-Type only (via the built-in potentiometer)
Adjustable for A/AB-Type only (via the built-in potentiometer)
COLD START 65A(twidth=550 s measured at 50% Ipeak) at 230VACμ;Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
MAX. CASE TEMP.
Tcase=+90℃
(Please refer to "STATIC CHARACTERISTIC" section)
100 ~ 305VAC 142 ~ 431VDC
PF 0.97/115VAC, PF 0.95/230VAC, PF 0.92/277VAC@full load≧≧≧
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
84~150W Constant Voltage + Constant Current LED Driver
95 ~ 108%
Hiccup mode, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed
ELG-150-24
200mVp-p
3.2 ~ 6.25A
12 ~ 24V
24V
105W
6 ~ 12V
ELG-150-12
150mVp-p
5 ~ 10A
12V
84W
ELG-150-42
250mVp-p
1.8 ~ 3.57A
21 ~ 42V
42V
105W
ELG-150-36
250mVp-p
2.1 ~ 4.17A
18 ~ 36V
36V
105W
ELG-150-48
250mVp-p
1.56 ~ 3.13A
24 ~ 48V
48V
105W
±3.0%
±0.5%
±2.0%
21.6 ~ 26.4V
32.4 ~ 39.6V
37.8 ~ 46.2V
10.8 ~ 13.2V
43.2 ~ 52.8V
6.25A
10A
3.57A
4.17A
3.13A
±3.0%
±0.5%
±1.0%
±2.5%
±0.5%
±1.0%
±2.5%
±0.5%
±0.5%
±2.0%
±0.5%
±0.5%
ELG-150-54
350mVp-p
1.4 ~ 2.8A
27 ~ 54V
54V
105W
49 ~ 58V
2.8A
±2.0%
±0.5%
±0.5%
89%
88%
90%
90%
90%
91%
1.7A / 115VAC 0.9A / 230VAC 0.7A/277VAC
28 ~ 34V
14 ~ 18V
47 ~ 54V
41 ~ 48V
54 ~ 62V
59 ~ 68V
THD< 20%(@load 50%/115VC; @load 60%/230VAC; @load 75%/277VAC)≧≧ ≧
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
AUXILIARY DC OUTPUT
Nominal 15V(deviation 11.5~15.5V)@0.3A for BE-Type only
No load power consumption <0.5W for Blank / A / Dx / D2-Type
NO LOAD / STANDBY
POWER CONSUMPTION
Standby power consumption <0.5W for B / AB / DA-Type
Tcase=-40 ~ +90 (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)℃
150W
120W
150W
150.1W
150.2W
151.2W
200VAC ~ 305VAC
100VAC ~ 180VAC
RATED CURRENT
(for BE Type only)
5.6A
8A
3.2A
3.73A
2.8A
2.5A
(For BE Type only)
134.4W
96W
134.4W
134.28W
134.4W
135W
EFFICIENCY
(Typ.)(for BE Type only)
87%
86%
88%
88%
88%
89%
(Except for BE Type)
(For All the Types)
File Name:ELG-150-SPEC 2018-05-29
EMC IMMUNITY
MTBF
DIMENSIONOTHERS
NOTE
PACKING
Compliance to
EN55015
,EN61000-3-2 Class C (@load 60%) ; EN61000-3-3≧
,EAC TP TC 020; GB17743 GB17625.1,
219 63* *35.5mm (L*W*H)
EMC EMISSION
SAFETY &
EMC
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH℃
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
SAFETY STANDARDS
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level ( )surge immunity Line-Earth 6KV, Line-Line 4KV
,EAC TP TC 020
1. All parameters NOT specially mentioned are measured at 230VAC input, rated and 25 of ambient temperature.current ℃
2. Please refer to "DRIVING METHODS OF LED MODULE". For DA-Type, Constant Current region is 60%~100% of maximum voltage
under rated power delivery.
3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
4. Tolerance : includes set up tolerance, line regulation and load regulation.
5. De rating may be needed under low input voltages. Please .- refer to STATIC CHARACTERISTICS sections for details
6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 80 or less.℃
9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
10.The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher than 2000m(6500ft).℃℃
0.95Kg ; 16pcs/16.0kg/0.77CUFT
899.8K hrs min. Telcordia SR-332 (Bellcore) 313.66Khrs min. MIL-HDBK-217F (25 )℃
DALI STANDARDS
Compliance to IEC62386-101,102,207 for DA-Type only
UL8750 (except for BE-type),(type”HL”) CSA C22.2 No. 250.13-12;
IEC/EN/AS/NZS 61347-1,IEC/EN/AS/NZS 61347-2-13 independent,
EN62384 ,,BIS IS15885(for 12/12B/12DA/24/24B/24DA/36A/42/42A/48A/54 only)
EAC TP TC 004, ; IP65 or IP67 approvedGB19510.1,GB19510.14