■ RELIABILITY DATA
* This catalog contains the typical specification only due to the limitation of space. When you consider the purchase of our products, please check our specification.
For details of each product (characteristics graph, reliability information, precautions for use, and so on), see our Web site (http://www.ty-top.com/)
.
11. Over current
LA Type
No emission of smoke no firing.
CAL4
5 Type
LHL□□
□
There shall be no scorch or short of wire.
LHLC
08,LHLC10 : Th
ere shall be no firing.
FBA/FBR
FL05□
Type
FL0
6BT Type
【Test M
ethod and Remarks】
LHL□□
□/LA・CAL45 Type: Mea
suring current : Rated current×2
Duration : 5 min
.
Number of measuring : one time
8. Self resonance frequency
LA Type Within the specified tolerance
CAL45 Type
LHL□□
□
FBA/FBR
FL05□
Type
FL0
6BT Type
【Test M
ethod and Remarks】
LA :
Measuring equipment : Network analyzer (Anritsu MS620J or its equivalent)
LHL□□
□ (exce
pt LHLP) : Measuring equipment : (HP4191A, 4192A) its equivalent
9. Temperature characteristic
LA Type △L/L : Within ±5%
CAL45 Type
LHL□□
□ △L/L : Within ±7% (exc
ept LHLP16 : Within ±20%)
FBA/FBR
FL05□
Type
FL0
6BT Type
【Test M
ethod and Remarks】
LA :
Change of maximum inductance deviation in step 1 to 5
Step Temperature (℃)
1 20
2 ー25 (Minimum operating temperature)
3 20 (Standard temperature)
4 +85 (Maximum operating temperature)
5 20
LHL□□□ : Change of maximum inductance deviation in step 1 to 5
Temperature at ste
p 1 : 20℃
Temperature at ste
p 2 : Minimum operating temperature
Temperature at ste
p 3 : 20℃ (Standard temperature)
Temperature at ste
p 4 : Maximum operating temperature
Temperature at ste
p 5 : 20℃
10. Tensile strength test
LA Type
No abn
ormality such as cut lead, or looseness.CAL4
5 Type
LHL□□□
FBA/FBR No
abnormality such as cut lead, or looseness.
FL05□
Type No ab
normality such as cut lead, or looseness.
FL06BT Type
【Test M
ethod and Remarks】
LA :
Apply the stated tensile force progressively in the direction to draw terminal.
force (N) duration (s)
25 5
CA : Apply the stated tensile force progressively in the direction to draw terminal.
force (N) duration (s)
10 10
LHL□□□ : Apply the stated tensile force progressively in the direction to draw terminal.
Nominal wire diameter tensile φd (mm) force (N) duration (s)
0.3<φd≦0.5 5
30±50.5<φd≦0.8 10
0.8<φd≦1.2 25
FBA/FBR : The body of a component shall be fixed and a tensile force of 20±1N shall be applied to the lead wire in the axial diretion of the component during 10±1 seconds.
FL05R□ : Fi
x the body of a component in the direction to draw terminal,and gradually apply the tensile force of 4.9N.
7. DC Resisitance
LA Type
Within the specified tolerance
CAL4
5 Type
LHL□□
□
FBA/FBR
FL05□
Type
FL0
6BT Type
【Test M
ethod and Remarks】
LA, CA
: Measuring equipment : low ohmmeter (A&D AD5812 or its equivalent)
LHL□□
□・FB・FL : Me
asuring equipment : DC ohmmeter