http://www.tracopower.com Page 2 of 4
DC/DC Converters
THN 20 Series 20 Watt
Input Specifications
Input current at no load (at nominal input voltage) 12 Vin models: 10 mA typ
24 Vin models: 6 mA typ.
48 Vin models: 4 mA typ.
Input current at full load – 12 Vin 3.3 VDC models: 1510 mA typ.
(at nominal input voltage) other models: 1960 mA typ.
– 24 Vin 3.3 VDC models: 755 mA typ.
other models: 970 mA typ..
– 48 Vin 3.3 VDC models: 375 mA typ.
other models: 485 mA typ.
Start-up voltage / under voltage shut down 12 Vin models: 9 VDC / 8 VDC
24 Vin models: 18 VDC / 16 VDC
48 Vin models: 36 VDC / 33 VDC
Surge voltage (1 sec. max.) 12 Vin models: 25 V max.
24 Vin models: 50 V max.
48 Vin models: 100 V max.
Reflected input ripple current 30 mAp-p typ.
Conducted noise (input) EN 55022 class A, FCC part 15, level A
without external components
ESD (electrostatic discharge) EN 61000-4-2, air ±8 kV, contact ±6 kV,
perf. criteria A
Radiated immunity EN 61000-4-3, 10 V/m, perf. criteria A
Fast transient / Surge EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±2 kV perf. criteria A
With external input capacitor e.g. Nippon
chemi-con KY 200 µF, 100 V, ESR 48 mOhm
Conducted immunity EN 61000-4-6, 10 Vrms, perf. criteria A
Output Specifications
Voltage set accuracy ±1 %
Output voltage adjustment range 24 Vin models: –10 / +20 %
all other models: ±10 % only for single output models
Regulation – Input variation (Vmin – Vmax) single output models: 0.2 % max.
dual output models: 0.5 % max.
– Load variation (0 – 100%) single output models: 0.2 % max.
dual output models balanced load: 1.0 % max.
dual output models unbalanced load (25% /100%): 5.0 % max.
Minimum load not required
Ripple and noise (20 MHz bandwidth) single output models: 75 mVp-p typ. with external capacitor
dual output models: 100 mVp-p typ. with external capacitor
Temperature coefficient ±0.02 %/K
Output current limitation typ. 150 % of Iout max., Hiccup
Short circuit protection continuous, automatic recovery
Over voltage protection 3.3 VDC models: 3.7 – 5.4 Vout
5 VDC models: 5.6 – 7.0 Vout
12 VDC models: 13.5 – 19.6 Vout
15 VDC models: 16.8 – 20.5 Vout
Start up time (nominal Vin and constant resistive load) 30 ms typ. (for power on and remote on)
Transient response setting time 250 µs typ. (25% load step change)