Applications
Limit temperature monitoring
Features
Tinned leads
Manufacturer's logo and type designation
stamped on in white
Characteristics for sensing temperatures of
90 to 140 °C conform with DIN 44081
RoHS-compatible
Delivery mode
Cardboard strips (standard), cardboard tape
reeled or in Ammo pack on request
Dimensional drawing
Dimensions in mm
General technical data
Max. operating voltage (T
A
= 0 ... 40 °C) V
max
30 V DC
Measuring voltage
1)
(T
A =
40 °C ... T
sense
+5 K) V
meas
≤ 2.5 V DC
Max. measuring voltage
1)
For T
A
see table "Electrical
specifications"
V
meas,max
7.5 V DC
Rated resistance (V
PTC
≤ 2.5 V) R
R
≤ 100 Ω
Operating temperature range (V ≤ V
meas,max
) T
op
40/ T
sense
+23 °C
Operating temperature range (V = V
max
) T
op
0/+40 °C
1) V
meas
and V
meas,max
for 90 °C ≤ T
sense
≤ 140 °C acc. to DIN 44081.
Electrical specifications and ordering codes
T
sense
°C
R
(T
sense
∆T)
(VPTC ≤ 2.5 V)
Ω
R
(T
sense
+ ∆T)
(VPTC ≤ 2.5 V)
Ω
R
(T
sense
+ 15 K)
(V
PTC
≤ 7.5 V)
Ω
R
(T
sense
+ 23 K)
(V
PTC
≤ 7.5 V)
Ω
Ordering code
∆T = ±5 K
80 ≤ 570 ≥ 570 - ≥ 10 k B59100C0080A070
90 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0090A070
100 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0100A070
110 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0110A070
120 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0120A070
130 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0130A070
140 ≤ 550 ≥ 1330 ≥ 4 k - B59100C0140A070
Sensors
Limit temperature sensors, leaded disks, coated C100
Page 2 of 10Please read Cautions and warnings and
Important notes at the end of this document.