Technical Data Sheet
RPC-3.50
Mismatch
Jack
03K150-055S3
Rosenberger Hochfrequenztechnik GmbH & Co. KG
P.O.Box 1260 D-84526 Tittmoning Germany
www.rosenberger.de
Tel. : +49 8684 18-0
Email : info@rosenberger.de
Page
2 / 2
RF_35/09.14/6.2 Dieses Dokument ist urheberrechtlich geschützt ● This document is protected by copyright ● Rosenberger Hochfrequenztechnik GmbH & Co. KG
Electrical data
Frequency range DC to 26.5 GHz
VSWR 1.1 0.03, DC to 12 GHz
1.1 0.05, 12 GHz to 26.5 GHz
DC Resistance 55
Power handling ≤ 0.5 W
Mechanical data
Mating cycles 500
Maximum torque 1.70 Nm
Recommended torque 0.90 Nm
Gauge 0.00 mm to 0.04 mm
Environmental data
Operating temperature range
1
+20 °C to +26 °C
Rated temperature range of use
2
0 °C to +50 °C
Storage temperature range -40 °C to +85 °C
RoHS compliant
1
Temperature range over which these specification are valid.
2
This range is underneath and above the operating temperature range, within the mismatch is fully functional
and could be used without damage.
Declaration of calibration options
Factory Calibration
Standard delivery for this calibration standard includes a Factory Calibration. The Calibration Certificate issued
reports individual calibration results, traceable to national / international standards.
Accredited Calibration
Optional this calibration standard can be delivered with an Accredited Calibration (DAkkS) having the highest
confidence in the traceability. The DAkkS Calibration Certificate issued reports individual calibration results in
a complex format, traceable to national / international standards. Calibration results are reported in a dense
data set file. The uncertainties are smaller than in a Factory Calibration.
For further, more detailed information see application note AN001 on the Rosenberger homepage.
Calibration interval
Recommendation 12 months
Packing
Standard 1 pce in box
Weight 8.0 g/pce
Draft Date Approved Date Rev. Engineering change number Name Date
Herbert Babinger 17.10.14 Martin Moder 17.10.14 e00 14-1492 Herbert Babinger 17.10.14
While the information has been carefully compiled to the best of our knowledge, nothing is intended as representation or warranty on
our part and no statement herein shall be construed as recommendation to infringe existing patents. In the effort to improve ou
products, we reserve the right to make changes judged to be necessary.