cui.com
date 02/12/2013 │ page 2 of 4CUI Inc │ SERIES: VSUU-150 │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 90 264 Vac
frequency 47 63 Hz
current
at 115 Vac, full load
at 230 Vac, full load
2.0
0.8
A
A
inrush current
at 115 Vac, 25°C, full load, cold start
at 230 Vac, 25°C, full load, cold start
16
56
20
63
A
A
power factor correction full load at 90 ~ 240 Vac 0.95 0.97 1.0
OUTPUT
parameter conditions/description min typ max units
line regulation full load 0.5 1 %
load regulation at 230 Vac 3 5 %
temperature coefcient all output -0.04 0.04 %/°C
transient response full load to half load at 100 Vac 4 ms
start-up full load at 100 Vac 0.3 1 2 s
hold-up full load at 110 Vac 16 ms
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection 112 132 %
over current protection 110 150 %
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
primary to secondary
primary to earth ground
4,242
2,121
Vdc
Vdc
isolation resistance test voltage of 500 Vdc 50
MΩ
safety approvals UL/cUL, TUV-Baurart, CE, CISPR-22 class B, FCC part 15 class B, CB
EMI/EMC CISPR 22 class B, FCC part-15 class B
leakage current full load at 240 Vac 0.4 0.75 mA
RoHS compliant yes
MTBF 100,000 hrs
ENVIRONMENTAL
parameter conditions/description min typ max units
operating temperature 0 70 °C
storage temperature -40 85 °C
operating humidity 5 95 %
storage humidity 5 95 %