Contact insert-HC-B 6-I-CT-M-1648157
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
HEAVYCON male insert, B6 series, 6-pos., for crimp contacts
Why buy this product
For fast coding with plastic profile
Key Commercial Data
Packing unit 1 STK
GTIN
GTIN 4046356092272
Technical data
General
Note
For HEAVYCON ADVANCE and HEAVYCON housing of B6 type, crimp
contacts CK 2,5-ED (crimp contacts not included in the scope of supply).
Connection method Crimp connection
Number of connections per position 1
Degree of pollution 3
Overvoltage category III
Number of positions 6+PE
Insertion/withdrawal cycles ≥ 500
Size B6
Contact numbering 1 - 6
Conductor cross section 0.5 mm² ... 4 mm²
Connection cross section AWG 20 ... 12
Stripping length of the individual wire 7.5 mm
Assembly instructions
Coding also using the CP-HC (1686478) coding profiles. HC-B6../ HC-
B10..for two coding profiles. HC-B16../ HC-B24..for four coding profiles.
https://www.phoenixcontact.com/pi/products/1648157
08/18/2018Page2/4
Contact insert-HC-B 6-I-CT-M-1648157
Technical data
General
Connection
For housing type B6. Connectors may only be inserted when there is no
load/the power is switched off. Use a screwdriver to remove the crimp
contacts. The opening for the screwdriver is next to the opening where
the conductor is inserted.
Ambient conditions
Ambient temperature (operation) -40 °C ... 125 °C (including heating up of contacts)
Degree of protection IP20
Material data
Contact material Copper alloy
Contact surface material Ag (alternatively Au)
Contact carrier material PA
Standards/regulations
PA: Fire protection in rail vehicles - requirement sets R22 and R23 acc.
to DIN EN 45545-2 (Risk level HL1 - HL2)
PA: Fire protection in rail vehicles - requirement set R24 acc. to DIN EN
45545-2 (Risk level HL1 - HL3)
Electrical characteristics
Rated voltage (III/3) 500 V
Rated surge voltage 6 kV
Rated current 16 A
Standards and Regulations
Connection in acc. with standard CSA
Constructional and testing regulations DIN EN 61984
DIN EN 60664
IEC 60352
Flammability rating according to UL 94 V0
Environmental Product Compliance
China RoHS Environmentally friendly use period: unlimited = EFUP-e
No hazardous substances above threshold values
Drawings
https://www.phoenixcontact.com/pi/products/1648157
08/18/2018Page3/4
Contact insert-HC-B 6-I-CT-M-1648157
Schematic diagram
6
5
4
3
2
1
Connector pin assignment, connection side
Diagram
Ambienttemperature[°C]
Operating current[A]
0
8
4
32
28
24
20
16
12
20
20
0
0
40
40
60
60
80
80
100
100
120
120
B6
B10
1
2
=1,5mm
=2,5mm
2
2
1
2
B16
B24
B6
B10
B16
B24
Derating diagram
Dimensional drawing
50,5
44
32
34
27
Male insert
Dimensional drawing
27
20
35
36
46
44
Ø3,4
Mounting cutout when used without housing
Dimensional drawing
A
B
32
34
27
Approvals
Approvals
Approvals
CSA / UL Recognized / cUL Recognized / EAC / cULus Recognized
Ex Approvals