FN2070M-12-06

DATASHEET
Two-Stage Filters FN 2070
Multi-stage Performance AC/DC EMI Filter
Rated currents from 1 to 36 A
High differential and common-mode
attenuation
High frequency attenuation
Optional medical versions (B type)
Optional safety versions (A type)
Performance indicators
Technical specifications
Rated voltage*
250 VAC, 50/60 Hz; 250 VDC
Operating frequency
DC to 400 Hz
Rated currents
1 to 36 A @ 40°C max.
High potential test voltage
P –> PE 2000 VAC for 2 sec
P –> PE 2500 VAC for 2 sec (B types)
P –> N 1100 VDC for 2 sec
Temperature range (operation and storage)
-25°C to +100°C (25/100/21)
Certified to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 (applies to
AC and DC applications)
Flammability corresponding to
UL 94 V-2 or better
Design corresponding to
UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 40°C/230 V (Mil-HB-217F)
1,550,000 hours
1,600,000 hours (B types)
*maximum RMS operating voltage at rated frequency or the maximum DC operating voltage
Approvals
Features and benefits
FN 2070 two-stage filters are designed for easy and
fast chassis mounting
FN 2070 filters are also available as B versions
without Y-capacitors for medical applications as well
as A version with low capacitance for safety critical
applications with necessity for low leakage currents
All filters provide a high conducted attenuation
performance, based on chokes with high saturation
resistance and excellent thermal behavior
FN 2070 two-stage filters are designed for high
frequency attenuation
FN 2070 filters are also available as single- stage
filters (FN 2030 series)
FN 2070 filters are also available with differential
mode choke (FN 2080 series)
Various terminal options allow you to select the
desired connection style
Typical applications
Electrical and electronic equipment
Consumer goods
Household equipment
Building automation
Industrial applications
Machinery
Medical equipment
Electronic data processing equipment
Office automation and datacom equipment
Various noisy applications requiering good filter
performance
Single Phase Motor Drives
Typical electrical schematic
2 EMC/EMI Products Schaffner Group Datasheets 2017
Filter selection table
Filter* Rated current Leakage current** Inductance Capacitance Resistance Input/Output Weight
@ 40°C (25°C) @ 250 VAC/50 Hz L Cx Cy R connections
(@ 120 VAC/60 Hz)
[A] [mA] [mH] [μF] [nF] [kΩ]
[g]
FN 2070-1-.. 1 (1.2) 0.66 (0.38) 22 0.33 4.7 1000 -06 -07 190
FN 2070-3-.. 3 (3.5) 0.66 (0.38) 9.8 0.47 4.7 470 -06 -07 250
FN 2070-6-.. 6 (6.9) 0.66 (0.38) 7.8 1 4.7 220 -06 -07 450
FN 2070-10-.. 10 (11.5) 0.66 (0.38) 4.5 1 4.7 220 -06 -07 670
FN 2070-12-.. 12 (13.8) 0.66 (0.38) 3.25 1 4.7 220 -06 -07 670
FN 2070-16-.. 16 (18.4) 0.66 (0.38) 2.8 1 4.7 220 -06 -07 -08 1000
FN 2070-25-08 25 (28.8) 0.66 (0.38) 2 2.2 4.7 220 -08 760
FN 2070-36-08 36 (41.4) 0.66 (0.38) 1.23 2.2 4.7 220 -08 790
FN 2070 A-1-.. 1 (1.2) 0.07 (0.04) 22 0.33 0.47 1000 -06 -07 190
FN 2070 A-3-.. 3 (3.5) 0.07 (0.04) 9.8 0.47 0.47 470 -06 -07 250
FN 2070 A-6-.. 6 (6.9) 0.07 (0.04) 7.8 1 0.47 220 -06 -07 450
FN 2070 A-10-.. 10 (11.5) 0.07 (0.04) 4.5 1 0.47 220 -06 -07 670
FN 2070 A-12-.. 12 (13.8) 0.07 (0.04) 3.25 1 0.47 220 -06 -07 670
FN 2070 A-16-.. 16 (18.4) 0.07 (0.04) 2.8 1 0.47 220 -06 -07 -08 1000
FN 2070 A-25-08 25 (28.8) 0.07 (0.04) 2 2.2 0.47 220 -08 760
FN 2070 A-36-08 36 (41.4) 0.07 (0.04) 1.23 2.2 0.47 220 -08 790
FN 2070 B-1-.. 1 (1.2) 0.00 22 0.33 1000 -06 -07 190
FN 2070 B-3-.. 3 (3.5) 0.00 9.8 0.47 470 -06 -07 250
FN 2070 B-6-.. 6 (6.9) 0.00 7.8 1 220 -06 -07 450
FN 2070 B-10-.. 10 (11.5) 0.00 4.5 1 220 -06 -07 670
FN 2070 B-12-.. 12 (13.8) 0.00 3.25 1 220 -06 -07 670
FN 2070 B-16-.. 16 (18.4) 0.00 2.8 1 220 -06 -07 -08 1000
FN 2070 B-25-08 25 (28.8) 0.00 2 2.2 220 -08 760
FN 2070 B-36-08 36 (41.4) 0.00 1.23 2.2 220 -08 790
Enhanced performance
FN 2070 M-1-06 1 (1.2) 3.69 (2.13) 22 0.33 47 1000 -06 170
FN 2070 M-3-06 3 (3.5) 3.69 (2.13) 9.8 0.47 47 470 -06 250
FN 2070 M-6-06 6 (6.9) 3.69 (2.13) 7.8 1 47 220 -06 450
FN 2070 M-10-06 10 (11.5) 3.69 (2.13) 4.5 1 47 220 -06 670
FN 2070 M-12-06 12 (13.8) 3.69 (2.13) 3.25 1 47 220 -06 670
FN 2070 M-16-.. 16 (18.4) 3.69 (2.13) 2.8 1 47 220 -06 -08 1000
FN 2070 M-25-08 25 (28.8) 3.69 (2.13) 2 2.2 47 220 -08 750
FN 2070 L-36-08 36 (41.4) 2.59 (1.49) 1.23 2.2 33 220 -08 790
*
* To compile a complete part number, please replace the -.. with the required I/O connection style (e.g. FN 2070-25-08, FN 2070B-10-06).
** Maximum leakage under usual AC operating conditions (acc. IEC 60939-3). Note: if the neutral line is interrupted, worst case leakage could reach twice this level.
Leakage current for DC application is 0 mA;
3 EMC/EMI Products Schaffner Group Datasheets 2017
Typical filter attenuation
Per CISPR 17; A=50 Ω/50 Ω sym; B=50 Ω/50 Ω asym; C=0.1 Ω/100 Ω sym; D=100 Ω/0.1 Ω sym
Standard Types
1 A types
3 A to 12 A types
16 A types
25 and 36 A types
Enhanced Performance Types
1 A types
3 A to 12 A Types
16 A Types
25 A and 36 A Types

FN2070M-12-06

Mfr. #:
Manufacturer:
Schaffner
Description:
Power Line Filters 12A FASTON GENERAL PURPOSE FLTR
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union