CPC1943GS

I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
DS-CPC1943-R08
1
CPC1943
Optically Coupled
AC Power Switch
Part # Description
CPC1943G 6-Pin Dip (50/Tube)
CPC1943GS 6-Pin Surface Mount (50/Tube)
CPC1943GSTR 6-Pin Surface Mount (1000/Reel)
Parameter Rating Units
Blocking Voltage 400 V
P
Load Current 500 mA
rms
On State Voltage Drop 1.4 V
rms
(at I
L
= 500mA
rms
)
Applications
Features
Description
Ordering Information
Pin Configuration
Programmable Control
Process Control
Power Control Panels
Remote Switching
Gas Pump Electronics
Contactors
Large Relays
Solenoids
Motors
Heaters
Load Current up to 0.5A
rms
400V
P
Blocking Voltage
5mA Sensitivity
Zero-Crossing Detection
DC Control, AC Output
Optically Isolated
TTL and CMOS Compatible
Low EMI and RFI Generation
High Noise Immunity
Machine Insertable, Wave Solderable
Flammability classification rating of V-0
Approvals
UL 508 Certified Component: File E69938
CSA Certified Component: File 043639
The CPC1943 is an AC Solid State Switch using
optical coupling with dual power SCR outputs to
produce an alternative to optocoupler and Triac
circuits. The CPC1943 switches are robust enough to
provide a blocking voltage of up to 400V
P
. In addition,
tightly controlled zero cross circuitry ensures switching
of AC loads without the generation of transients.
The input and output circuits are optically coupled
to provide 3750V
rms
of isolation and noise immunity
between control and load circuits. As a result the
CPC1943 is well suited for industrial environments
where electromagnetic interference could disrupt the
operation of electromechanical relays.
ZC
1
3
2
4
5
6
AC Load
AC Load
- LED
+ LED
I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R08
CPC1943
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameter Ratings Units
Blocking Voltage 400 V
P
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
100 mA
1A
Input Power Dissipation
1
150 mW
P
MAX
, Total Package Dissipation
2
800 mW
Isolation Voltage, Input to Output 3750 V
rms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Operating Voltage Range V
L
- 20 - 120 V
rms
Load Current, Continuous V
L
=120-240V
rms
I
L
0.005 - 0.5 A
rms
Off State Leakage Current V
L
=400V
P
I
LEAK
--1mA
On-State Voltage Drop I
L
=500mA
rms
V
ON
- - 1.4 V
rms
Critical Rate of Rise
3
- dV/dt 1000 - - V/µs
Switching Speeds
Turn-on
I
F
=5 mA
t
on
- - 0.5
cycles
Turn-off t
off
- - 0.5
Zero-Cross Turn-On Voltage
1
1st half cycle - - 2 10 V
Subsequent half cycle - - 1 - V
Operating Frequency - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On
2
- PF 0.25 - - -
Input Characteristics
Input Control Current to Activate
4
-I
F
- 0.8 5 mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Input Drop-out Voltage - 0.8 - - V
Reverse Input Current V
R
=5V I
R
- - 10 µA
Common Characteristics
Input to Output Capacitance - C
I/O
-3-pF
1
Zero Cross 1st half cycle @ <100Hz
2
Snubber circuits may be required at low power factors.
3
Tested in accordance with EIA/NARM standard RS-443.
4
For high noise environments, use I
F
=10mA.
I
NTEGRATED
C
IRCUITS
D
IVISION
CPC1943
www.ixysic.com
3
R08
PERFORMANCE DATA*
*The Performance data shown in the graphs above is typical of device performance. For guaranteed parameters not indicated in the written specifi cations, please
contact our application department.
LED Forward Voltage (V)
1.25 1.26 1.27 1.28 1.29 1.30
Device Count (N)
0
5
10
15
20
25
30
35
Typical LED Forward Voltage Drop
(T
A
=25ºC, I
F
=5mA)
On-State Voltage (V
rms
)
0.91 0.94 0.96 0.99 1.02 1.04
Device Count (N)
0
5
10
15
20
25
Typical On-State Voltage Distribution
(T
A
=25ºC, I
L
=500mA
rms
)
Blocking Voltage (V
P
)
565 570 575 580 585 590 595
Device Count (N)
0
5
10
15
20
Typical Blocking Voltage Distribution
(T
A
=25ºC)
LED Current (mA)
0.77 0.78 0.79 0.80 0.81 0.82 0.83
Device Count (N)
0
5
10
15
20
Typical I
F
for Switch Operation
(T
A
=25ºC, I
L
=500mA
rms
)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Currrent (mA)
0.65
0.70
0.75
0.80
0.85
0.90
0.95
Typical I
F
for Switch Operation
vs. Temperature
(I
L
=250mA
rms
)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Leakage (PA)
130
140
150
160
170
180
Typical Leakage Current
vs. Temperature
(V
L
=400V
P
)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Blocking Voltage (V
P
)
500
550
600
650
700
Typical Blocking Voltage
vs. Temperature
Temperature (ºC)
-40 -20 0 20 40 60 80 100
On-State Voltage (V
rms
)
0.80
0.85
0.90
0.95
1.00
1.05
1.10
Typical On-State Voltage
vs. Temperature
(I
L
=250mA
rms
)
Temperature (ºC)
-40 -20 0 20 40 60 80 100
LED Forward Voltage (V)
1.1
1.2
1.3
1.4
1.5
1.6
Typical LED Forward Voltage Drop
vs.Temperature
I
F
=50mA
I
F
=5mA
I
F
=10mA
I
F
=20mA
Temperature (ºC)
-40 -20 0 20 40 60 80 100
Load Current (mA
rms
)
250
300
350
400
450
500
550
Load Current, Free Air
vs. Temperature
Typical dV/dt vs. Temperature
Critical Rate of Rise (V/Ps)
0
800
600
400
200
1200
1000
25 50 85
Temperature (ºC)
Vo
63%
10%
RC
Vo = 300V
dv 0.63 x 300V 189
dt RC RC
In accordance with
EIA/NARM Standards
RS-443 for Solid State Relays
dV/dt Method

CPC1943GS

Mfr. #:
Manufacturer:
IXYS Integrated Circuits
Description:
Triac & SCR Output Optocouplers 400V, 500mA AC Power Switch
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union

Products related to this Datasheet