I
NTEGRATED
C
IRCUITS
D
IVISION
www.ixysic.com
2
R08
CPC1943
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Absolute Maximum Ratings @ 25ºC
Electrical Characteristics @ 25ºC
Parameter Ratings Units
Blocking Voltage 400 V
P
Reverse Input Voltage 5 V
Input Control Current
Peak (10ms)
100 mA
1A
Input Power Dissipation
1
150 mW
P
MAX
, Total Package Dissipation
2
800 mW
Isolation Voltage, Input to Output 3750 V
rms
Operational Temperature -40 to +85 °C
Storage Temperature -40 to +125 °C
1 Derate linearly 1.33 mW / ºC
2 Derate linearly 6.67 mW / ºC
Parameters Conditions Symbol Min Typ Max Units
Output Characteristics
Operating Voltage Range V
L
- 20 - 120 V
rms
Load Current, Continuous V
L
=120-240V
rms
I
L
0.005 - 0.5 A
rms
Off State Leakage Current V
L
=400V
P
I
LEAK
--1mA
On-State Voltage Drop I
L
=500mA
rms
V
ON
- - 1.4 V
rms
Critical Rate of Rise
3
- dV/dt 1000 - - V/µs
Switching Speeds
Turn-on
I
F
=5 mA
t
on
- - 0.5
cycles
Turn-off t
off
- - 0.5
Zero-Cross Turn-On Voltage
1
1st half cycle - - 2 10 V
Subsequent half cycle - - 1 - V
Operating Frequency - 20 - 500 Hz
Load Power Factor for Guaranteed Turn-On
2
- PF 0.25 - - -
Input Characteristics
Input Control Current to Activate
4
-I
F
- 0.8 5 mA
Input Voltage Drop I
F
=5mA V
F
0.9 1.2 1.4 V
Input Drop-out Voltage - 0.8 - - V
Reverse Input Current V
R
=5V I
R
- - 10 µA
Common Characteristics
Input to Output Capacitance - C
I/O
-3-pF
1
Zero Cross 1st half cycle @ <100Hz
2
Snubber circuits may be required at low power factors.
3
Tested in accordance with EIA/NARM standard RS-443.
4
For high noise environments, use I
F
=10mA.