8
Regulatory Information
Insulation and Safety Related Specifications
Parameter Symbol Value Units Conditions
Minimum External Air Gap (Clearance) L(I01) 4.9 mm Measured from input terminals to output terminals,
shortest distance through air
Minimum Externa l Tracking(Creepage) L(I02) 4.5 mm Measured from input terminals to output terminals,
shortest distance path through body
Minimum Internal Plastic Gap (Internal Clearance) 0.08 mm Insulation thickness between emitter and detector;
also known as distance through insulation
Tracking Resistance (Comparative Tracking Index) CTI 175 Volts DIN IEC 112/VDE0303 Part 1
Isolation Group IIIa Material Group (DIN VDE 0110, 1/89, Table 1)
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics (Option X6X Only)
Description Symbol ACSL-6XX0-X6X Units
Installation Classification per DIN VDE 0110/1.89, Table 1
for rated mains voltage ≤ 150V rms I-IV
for rated mains voltage ≤ 300V rms I-III
Climatic Classification 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Maximum Working Insulation Voltage V
IORM
560 V
peak
Input to Output Test Voltage, Method b * V
PR
1050 V
peak
V
IORM
x 1.875 = V
PR
, 100% Production
Test with t
m
= 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a * V
PR
840 V
peak
V
IORM
x 1.5 = V
PR,
Type and Sample Test,
T
m
= 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage * V
IOTM
4000 V
peak
(Transient Overvoltage, t
ini
= 10 sec)
Safety Limiting Values
(Maximum values allowed in the event of a failure)
Case Temperature T
S
175 °C
Input Current I
S,INPUT
150 mA
Output Power P
S,OUTPUT
600 mW
Insulation Resistance at T
S
, V
IO
= 500V R
IO
10
9
Ω
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-2,
for a detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings, which must be ensured by protective circuits in application.