7-1618387-2

Ordering Information
Typical Part Number LEV200 A4NAA
Series:
LEV200 = 500+ Amp, 12-900Vdc Contactor
Contact Form:
A = Normally Open
H = Normally Open with Aux. Contacts. (Option
“H” requires option “A” in Coil Wire Length
and option “N” in Coil Terminal Connector.)
Note: Other auxiliary contact forms available.
Consult factory.
Coil Voltage:
4 = 12Vdc 5 = 24Vdc B = 28Vdc
6 = 48Vdc K = 72Vdc
8 = 96Vdc L = 110Vdc O = 115Vac 9 = 240Vac
Notes: Consult factory for detailed specifications
and availability of coils not listed in
“Coil Data” table above. In coil voltage
codes, 115Vac is designated by the
letter “O” rather than the numeral “0.”
Coil Wire Length:
A = 15.3 in (390 mm) N = None (Requires option
“A” in next step.)
Coil Terminal Connector:
N = None, stripped wires
(Requires option “A” in previous step.)
A = Studs, #10-32 Threaded (Electrical connection
is made to the tab at the base of the stud.)
Note: Specify option A, stripped wires, for coil voltages
> 96Vdc
Mounting & Power Terminals:
A = Bottom Mount & Male 10mm x M8 Threaded Terminals
F = Side Mount & Male 10mm x M8 Threaded Terminals
Consult factory regarding other available mountings and
power terminals.
7–32
KILOVAC High Voltage DC Contactors
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
KILOVAC LEV200 Series Contactor With 1 Form X
Contacts Rated 500+ Amps, 12-900Vdc
Performance Data
Contact Arrangement, Power
Contacts — 1 Form X (SPST-NO-DM)
Rated Operating Voltage
12 - 900 VDC
Continuous (Carry) Current,
Typical — 500 A @ 65°C, 400 mcm
conductors
Consult TE for required conductors for
higher (500+ A) currents
Make/Break Current at Various
Voltages
1
— See graph next page
Break Current at 320VDC
1
2,000 A, 1 cycle
3
Contact Resistance, Typ.
(@200A) — 0.2 mohms
Load Life — See graph next page
Mechanical Life — 1 million cycles
Contact Arrangement, Auxiliary
Contacts — 1 Form A (SPST-NO)
Aux. Contact Current, Max.
2A @ 30VDC / 3A @ 125VAC
Aux. Contact Current, Min.
100mA @ 8V
Aux. Contact Resistance, Max.
0.417 ohms @ 30VDC /
.150 ohms @ 125VAC
Operate Time @ 25°C
Close (includes bounce), Typ. — 25 ms
Bounce (after close only), Max. — 7 ms
Release (includes arcing), Max @
2000A — 12 ms
Dielectric Withstanding Voltage
2,200 Vrms @ sea level (leakage <1mA)
Insulation Resistance @ 500VDC
100 megohms
2
Shock, 11ms 1/2 Sine, Peak,
Operating — 20 G
Vibration, Sine, 80-2000Hz.,
Peak — 20 G
Operating Ambient Temperature
-40°C to +85°C
Weight, Typical — 1.3 lb. (.60 kg)
Notes:
1
Main power contacts
2
50 at end of life
3
Does not meet dielectric & IR after
test, 1700 amp for unit with Aux.
Contacts
4
Contacts will operate with 0.8V
nom
< V
coil
< 1.1V
nom
over temperature
range.
C
oil Data (Valid Over Temperature Range)
4
N
ominal Voltage 12Vdc 24Vdc 48Vdc 72Vdc
Pickup Voltage (Will Operate) 9.0Vdc 19.0Vdc 38.0Vdc 57.0Vdc
Voltage (Max.) 15Vdc 30Vdc 60Vdc 90Vdc
D
ropout Voltage 0.75 - 1.0 - 2.0 - 3.0 -
2
.0Vdc 5.0Vdc 7.0Vdc 12.0Vdc
Coil Resistance @ 25° (Typ.) 11 ohms 40 ohms 145 ohms 357 ohms
Product Facts
n Designed to be the lowest
cost sealed contactor in the
i
ndustry with its current
rating (500+A carry, 2000A
interrupt at 320Vdc)
n Available with bottom or
side mounting — not
p
osition sensitive
n Optional auxiliary contact
for easy monitoring of
power contact position
n Hermetically sealed —
intrinsically safe, operates
in explosive/harsh
environments with no
oxidation or contamination
of coils or contacts,
including long periods of
non-operation
n Typical applications include
battery switching and
backup, DC voltage power
control, circuit protection
and safety
n Versatile coil/power
connections
n Designed and built in
accordance to AIAG QS9000
n RoHS compliant
Invalid
Combinations/Reason
LEV200H-NA_
No auxiliary function with coil studs
LEV200_ONA_
No coil studs with rectifier circuit
LEV200_9NA_
No coil studs with rectifier circuit
LEV200_O_F
No side mont with rectifier circuit
LEV200_9_F
No side mount with rectifier circuit
7–33
KILOVAC High Voltage DC Contactors
KILOVAC High Voltage
DC Contactors
7
For factory-direct application assistance,
dial 800-253-4560, ext. 2055, or
805-220-2055.
Catalog 5-1773450-5 Dimensions are shown for Dimensions are in millimeters USA: +1 800 522 6752 For additional support numbers
Revised 3-13 reference purposes only. unless otherwise specified. Asia Pacific: +86 0 400 820 6015 please visit www.te.com
Specifications subject UK: +44 800 267 666
www.te.com to change.
KILOVAC LEV200 Series (Continued)
Outline Dimensions
Estimated Make & Break Power Switching Ratings
NOTES:
1) For resistive loads with 300µH maximum inductance. Consult factory for inductive loads.
2) Estimates based on extrapolated data. User is encouraged to confirm performance in application.
3) End of life when dielectric strength between terminals falls below 50 megohms @ 500VDC.
4) The maximum make current is 650A to avoid contact welding.
100,000
10,000
1,000
100
10
1
1,000
10,000
100101
Make and Break Power Switching Region Break Only Above 650A
650A
Estimated Life (Cycles)
Load Current (A)
18
00 VDC
90
0
VDC
6
0
0
VDC
4
0
0
V
DC
2
7
0
VD
C
120 VDC
2
8
V
DC
Time (ms)
Current (A)
LEV200 Capacitive Make Test Curves for Pre-Charged Motor Controller
650
600
550
500
450
400
350
300
250
200
150
100
50
0
0.0 0.5 1.0 1.5 2.0
80% Minimum
Pre Charge
90% Nominal
Pre Charge
700
SIde Mount Enclosure
Bottom Mount Enclosure
Note: When stud terminals are
s
pecified for coil connections,
the electrical connection is
m
ade at the tab located at the
b
ase of the stud.

7-1618387-2

Mfr. #:
Manufacturer:
TE Connectivity / Kilovac
Description:
General Purpose Relays LEV200A5ANF
Lifecycle:
New from this manufacturer.
Delivery:
DHL FedEx Ups TNT EMS
Payment:
T/T Paypal Visa MoneyGram Western Union