971-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
ZWS-BP Series
Features
Universal Input (85 - 265VAC)
Power factor Corrected
Up to 200% Peak Power capability
Five year warranty
Less than 0.5mA earth leakage current
150-480W Single Output Power Supplies
Notes:
(1) 100/200VAC
(2) 25°C ambient (cold start)
(3) Avoid prolonged operation in overload
Model ZWS150BP ZWS240BP
Input Voltage V 85-265VAC (47-63Hz), 120-370VDC* (Derate to 80% load below 90VAC Input)
Input Current A 1.9 / 0.95 2.8 / 1.5
Inrush Current (1)(2) A 14 / 28 15 / 30
Power Factor V 0.98 at 100VAC, 0.93 at 200VAC, Meets EN61000-3-2
Leakage Current mA 0.5mA Max. Typically 0.2mA (100VAC), 0.4mA (230VAC)
Temperature Coeffi cient %/°C <0.02%/°C
Overcurrent Protection (3) - >101% of peak current capability (constant current style)
Overvoltage Protection V 24V: 27.6-32.4V, 36V: 41.4-48.6, 48V: 55.2-64.8V
Hold Up Time (Typ) (1) ms 20
Effi ciency (1) % 87 / 90% 88 / 91%
Remote On/Off - Optional, contact factory
Line Regulation % 0.4%
Load Regulation % 0.8%
Ripple & Noise % 1%
Operating Temperature °C -10°C to +70°C, derate linearly to 50% load from 50°C to 70°C
Storage Temperature °C -30 to +75°C
Humidity (non condensing) %RH Operating: 30 - 90%RH, Storage: 10 - 90%RH
Cooling - Convection
Withstand Voltage - Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (20mA) for 1 min.
Isolation Resistance - >100M at 25°C & 70%RH, Output to Ground 500VDC
Vibration (non operating) - 10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour each
Shock - < 196.1 m/s
2
Safety Agency Certifi cations - UL60950-1, CSA60950-1, EN60950-1, EN50178 OV II, CE Mark
Conducted & Radiated EMI - EN55011/EN55022-B, FCC Class B, VCCI-B
Immunity - EN61000-4-2 (lvl2, 3), -3 (lvl 3), -4 (lvl 3), -5 (lvl 3, 4), -6 (lvl 3), -8 (lvl 4), -11
Weight (Typ) g 360g 520g
Size (WxHxD) in(mm) 2.95 x 1.46 x 6.3 (75 x 37 x 160) 3.31 x 1.65 x 7.09 (84 x 42 x 180)
Warranty yrs Five Years
Specifi cations
Key Market Segments & Applications
*Safety certifi ed for AC input only