5
IXA531
Static Electrical Characteristics
V
BIAS
(V
CL
, V
CH1,2,3
) = 15V unless otherwise specified. The V
IN
, V
TH
and I
IN
parameters are referenced to DG and are
applicable to all six channels . The V
O
and I
O
parameters are referenced to LS and V
HS1,2,3
and are applicable to the
respective output leads: H
GO1,2,3
and L
GO1,2,3
.
Symbol Definition Min. Typ. Max. Units Test Conditions
V
INL
Logic “0” input voltage HIN1,2,3; LIN1,2,3 0.8 V
V
INH
Logic “1” input voltage HIN1,2,3; LIN1,2,3 3.0 V
V
EN,TH+
EN positve going threshold 3.0 V
V
EN,TH -
EN negative going threshold 0.8 V
V
ITRP, TH+
ITRP positve going threshold 0.37 0.46 0.55 V
V
ITRP, HYS
ITRP input hysteresis .07 V
V
RST,TH+
RST positive going threshold 8 V
V
RST, HYS
RST input hysteresis 3 V
V
OH1,2,3
High level output voltage, V
CH -
V
HGO
or V
CL-
V
LGO
0.9 1.4 V I
0
=20mA
V
OL1,2,3
Low level output voltage, V
HGO or
V
LGO
0.4 0.6 V I
0
=20mA
VCLUV+ VCL supply under-voltage positive going threshold 10.6 11.1 11.6 V
V
CHUV+
V
CH
supply under-voltage positive going threshold
10.6 11.1 11.6
V
V
CLUV-
V
CL
supply under-voltage negaitive going threshold
10.4 10.9 11.4
V
V
CHUV-
V
CH
supply under-voltage negaitive going threshold 10.4 10.9 11.4 V
V
CLUVH
V
CL
supply under-voltage lockout hysteresis 0.2 V
V
CHUVH
V
CH
supply under-voltage lockout hysteresis 0.2 V
I
LK
Offset supply leakage current 50 μAV
CH1,2,3=
V
HS1,2,3=600 V
I
QVCH
Quiescent V
CH
supply current 70 120 μAV
IN
=0V or 5V
I
QVCL
Quiescent V
CL
supply current 1.6 2.3 mA V
IN
=0V or 5V
V
IN
Input clamp voltage (HIN,LIN,ITRP,EN) 4.9 V I
IN
= 100μA
I
LIN+or
I
IN+
Logic “1“ Input bias current for LIN1,2,3 200 300 μAV
LIN = 5V
I
LIN-or
I
IN-
Logic “0“ Input bias current for LIN1,2,3 100 220 μAV
LIN = 0V
I
HIN+or
I
IN+
Logic “1“ Input bias current for HIN1,2,3 200 300 μAV
HIN = 5V
I
HIN-or
I
IN-
Logic “0“ Input bias current for HIN1,2,3 100 220 μAV
HIN = 0V
I
ITRP+
“high” ITRP input bias current 30 100 μAV
ITRP = 5V
I
ITRP-
“low” ITRP input bias current 0 1 μAV
ITRP = 0V
I
EN+
“high” ENABLE input bias current 30 100 μAV
EN = 5V
I
EN-
“low” ENABLE input bias current 0 1 μAV
EN = 0V
I
RST
RST input bias current 0 1 μAV
RST = 0Vor 15V
I
GO+
Output high short circuit pulsed current 600 mA V
0
=0V,PW <10 μs
I
GO-
Output low short circuit pulsed current 600 mA V
0
=15V,PW<10μs
R
ON, RST
RST low on resistance 50 100 Ω
R